AQUAPHOR CRYSTAL H-80-2 Kullanıcı Kılavuzu - Sayfa 8

Dış Mekan Çeşmesi AQUAPHOR CRYSTAL H-80-2 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. AQUAPHOR CRYSTAL H-80-2 12 sayfaları. Drinking water fountain

AQUAPHOR CRYSTAL H-80-2 Kullanıcı Kılavuzu
6
Filter cartridges replacement:
The replaceable filter cartridges originally installed in the dispenser are right for the model.
It is recommended to replace the filter cartridges in a timely manner.
REMEMBER that a dispenser with used cartridges is unusable.
- turn off the water at the connection and open the tap (5) for fresh water in order to
relieve the pressure.
- pressing it hard and holding the safety button (14), turn the used filter cartridge counter
clockwise (fig. 5);
- remove the protective foil from the new cartridge;
- insert the new cartridge into the cabinet (14), pressing it carefully, and gently turn it
clockwise (fig. 6).
Follow the correct sequence when replacing cartridges as shown in Fig. 6.
- then follow the steps in the chapter " Following the water fountain installation and
connection".
KH cartridge regeneration
Fig. 7
THE WATER FOUNTAIN OPERATION
1
2
1 - push
2 - turn
Fig. 5
- perform the first two steps in the "Filter cartridges
replacement" section;
- then assemble the regeneration adapter (1) and connect it
to the KH insert (included in the set or purchased
separately) (fig. 6):
- place the washer (3) on the nut (2);
- put the nut (2) with the washer (3) on the adapter (1),
pressing it as far as it will go;
- put the plastic hose (4) on the stump on the adapter (1);
- firmly insert the adapter (1) in the insert (6);
- screw an ordinary clean plastic bottle (5) with a cut-off
bottom (funnel-shaped) onto the nut (2);
2
1
Fig. 6
1 - insert
2 - turn