Bypass Assembly
The use of a bypass assembly is recommended as it will allow you
to isolate the UV Reactor. This will allow for easier access in case
maintenance is required.
3
COPPER PIPES ONLY (proceed to the next step for PVC pipes)
When installing on metallic plumbing, ensure you take the following
precautions. Securely install two (2) grounding clamps and a #4 copper
wire (not included) across the location where the system will be installed.
Tightly clamp at both ends, as shown in the illustration.
Ground
Clamp
ELECTRICAL SHOCK Hazard
plumbing, securely install two grounding clamps and a #4 copper
wire per installation instructions. Failure to follow these instructions
can result in death or electric shock.
Ground Wire
WARNING
-
Prior to installation on metallic