Aquasana OptimH2O AQ-RO-3 Kullanıcı El Kitabı - Sayfa 7

Su Filtrasyon Sistemleri Aquasana OptimH2O AQ-RO-3 için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Aquasana OptimH2O AQ-RO-3 11 sayfaları. Whole house water filter
Ayrıca Aquasana OptimH2O AQ-RO-3 için: Kullanıcı El Kitabı (14 sayfalar), Kullanıcı El Kitabı (10 sayfalar), Kullanıcı El Kitabı (16 sayfalar)

Aquasana OptimH2O AQ-RO-3 Kullanıcı El Kitabı
3-STAGE RO SYSTEM – MODEL AQ-RO-3
Membrane Production
1
Membrane TDS Reduction
1
System Production
2
TDS Reduction
2
Maximum TDS
Maximum water hardness @ 6.9pH
Maximum Chlorine in water
Supply water pH limits
Drain (reject water) Flow
Empty Storage Tank Precharge
Storage Tank Capacity
2
Supply water pressure limits
Supply water temperature limit
Efficiency
3
Recovery
4
Capacity at various water pressure levels (with 5 psi precharge)
Total Volume
20 psi
30 psi
3.2
1.4
1.8
U.S.
Metric
35 gpd
132 lpd
95% minimum
95% minimum
13.32 gpd
50.4 lpd
96.3%+ average
96.3%+ average
1000 ppm
1000 ppm
10 gpg
2.64 gpL
3.0 ppm
3.0 ppm
4-10
4-10
3-5 x product flow
3-5 x product flow
5-7 psi air
35-48 kPa air
3.2 gallons
12.11 liters
40-100 psi
275-689 kPa
40-100⁰ F
5-37⁰ C
17.91%
17.91%
29.43%
29.43%
U.S. Gallons
40 psi
50 psi
60 psi
2.0
2.2
2.4
Specifications – Qualified System Performance
Because the performance of a Reverse Osmosis Membrane is highly dependent upon pressure,
temperature and TDS, the following should be used for comparison purposes only.
1 Industry standards measure RO Membranes performance with no back pressure on the
product water, at 60 psig (414kPa) and 77°F (25°C). Further conditions on the above are 250
ppm TDS and a 30.6% recovery rate. Production rate and TDS reduction figures are for a new
Membrane that has been rinsed for 24 hours. The production rate of a new Membrane can
decrease by 10% per year or more, depending upon the scaling and fouling tendencies of the
Feed Water.
2 Measured at 50 psi, 77°±2°F, and 717 mg/l TDS per NSF/ANSI Standard 58.
3 Efficiency rating means the percentage of the influent water to the system that is available
to the user as reverse osmosis treated water. Under operating conditions that approximate
typical daily usage.
4 Recovery rating means the percentage of the influent water to the membrane portion of
the system that is available to the user as reverse osmosis treated water when the system is
operated without a storage tank or when the storage tank is bypassed.
Do not use with water that is microbiologically unsafe or of unknown water quality
without adequate disinfection before or after the system. Systems certified for cyst
reduction may be used on disinfected waters that may contain filterable cysts.
Filter is only to be used with cold water. Systems certified for cyst reduction may be
used on disinfected water that may contain filterable cysts.
70 psi
Non-potable Water Sources:
2.5
Do not attempt to use this product to make safe drinking water from non-potable water
sources. Do not use the system on microbiologically unsafe water, or water of unknown quality
without adequate disinfection before or after the system. This system is certified for cyst
reduction and may be used on disinfected water that may contain filterable cysts.

Installations in The Commonwealth of Massachusetts:

The Commonwealth of Massachusetts requires installation be performed by a licensed plumber
and do not permit the use of saddle valves. Plumbing code 248—CMR of the Commonwealth of
Massachusetts must be followed in these cases.