AquaScape 45010 Talimatlar ve Bakım - Sayfa 7

Su Pompası AquaScape 45010 için çevrimiçi göz atın veya pdf Talimatlar ve Bakım indirin. AquaScape 45010 20 sayfaları. Adjustable flow pond pump
Ayrıca AquaScape 45010 için: Talimatlar ve Bakım (20 sayfalar)

AquaScape 45010 Talimatlar ve Bakım
NOTE: Do not remove the outer or inner filter screens
while operating the pump, as failure to do so may cause
the pump to fail, voiding the warranty.
• The outer screen is designed to pop off when it is gently
pulled from either side (Ex. 15).
• The inner filter screen can be removed by unscrewing
counterclockwise (Ex. 16).
NOTE: Be sure to replace the screens before operating
the pump, as failure to do so may cause the pump to fail,
voiding the warranty.
Impeller/Rotor Cleaning
• Remove the four screws to disconnect the water
chamber cover (Ex. 17).
aquascapeinc.com |
CAN (866) 766-3426 |
• Remove the impeller by pulling gently (Ex. 18).
Ex. 15
• Clean the impeller and internal pump body with Aquascape
Pump Cleaner Maintenance Solution (#91143), using a
sponge or soft-bristle brush (Ex. 19).
Ex. 16
• Re-install the impeller, making sure the gasket is in place
and the raised key on the impeller flange is aligned with the
matching notch in the face of the pump flange (Ex. 20).
US (866) 877-6637
Ex. 17
Ex. 18
Ex. 19
Ex. 20
7