Increasing pump size will increase flow. When in doubt, consult your pool and spa professional.
Never use a pool or spa that has a missing or broken suction outlet cover.
Using a pool or spa with a missing or broken suction outlet cover can result in hair or body entrapment which can cause
severe bodily injury or death. The vacuum in suction outlets and/or suction outlet covers that are damaged, broken,
cracked, missing or unsecured can cause severe injury and/or death due to the following entrapment hazards:
HAIR ENTRAPMENT – Hair can become entangled in suction outlet cover.
LIMB ENTRAPMENT – A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged,
broken, cracked, missing or not securely attached can result in a mechanical bind or swelling of the limb.
BODY SUCTION ENTRAPMENT – A negative pressure applied to a large portion of the body or limbs can result in
an entrapment.
EVISCERATION/DISEMBOWELMENT ENTRAPMENT – A negative pressure applied directly to the intestines through an
unprotected suction outlet sump or suction outlet cover which is damaged, broken, cracked, missing or unsecured
can result in evisceration/disembowelment entrapment.
MECHANICAL ENTRAPMENT – There is a potential for jewelry, swimsuit, hair decorations, a finger, a toe or a knuckle
to be caught in an opening of a suction outlet cover resulting in mechanical entrapment.
WARNING! TO REDUCE THE RISK OF ENTRAPMENT HAZARD
If not an approved single, unblockable outlet, a minimum of two functioning suction outlets per pump must be
installed. Suction outlets in the same plane (i.e. floor or wall) must be installed a minimum of three feet (1 meter) apart,
as measured from near point to near point. Dual suction fittings shall not be located on seating areas or on the backrest
for such seating areas. If any suction outlets are located closer they shall be located on two different planes (i.e. one on
the bottom and one on the vertical wall, or one each on two separate vertical walls). The maximum system flow rate
shall not exceed the flow rating of any listed (per ASME/ANSI A112.19.8-2007) suction outlet cover installed. Never use
pool or spa if any suction outlet component is damaged, broken, cracked, missing or not securely attached. Replace
damaged, broken, cracked, missing or not securely attached suction outlet components immediately. In addition to two
or more suction outlets per pump installed in accordance with latest APSP, IAF Standards and CPSC guidelines, follow
all national, state and local codes applicable. Use only transitional (typically green) glues when attaching PVC pipe to
ABS fittings. Use gray medium set glue when attaching PVC pipe to our PVC based skimmers and double-deep sump
buckets. In both cases, do not ever use blue glue or related hot glues, clear glues or any fast-setting cement.
WARNING! – Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction
outlets can result in increased potential for suction entrapment as described above.
WARNING! – Failure to keep suction outlet components clear of debris such as leaves, dirt, hair, paper and other material
can result in increased potential for suction entrapment as described above.
WARNING! – Suction outlet components have a finite life; the cover/grate should be inspected before each use of facility
and replaced at least every five years or if found to be damaged, broken, cracked, missing, not securely attached or
missing screws. DO NOT use facility until corrected!
As the manufacturer, AquaStar Pool Products, Inc., hereby certifies that its suction outlet and drain covers meet or exceed
the requirements of the Virginia Graeme Baker Pool & Spa Safety Act, VGB 2008 and ANSI/APSP-16 2011 standards and
safety regulations as set forth by the U.S. Consumer Products Safety Commission.
A copy of this certificate is available on the AquaStar Pool Products, Inc. website under news & information:
www.aquastarpoolproducts.com
877.768.2717 fax 877.276.POOL Outside the U.S.: +1.805.620.5060 fax +1.949.336.1940