For discharging(OUT)
Maintenance & Inspection:
⚫ Strainer is placed in air-valve for cleaning the clogged rubbish.
Photo-3
Strainer is placed in air valve.
Make it clean,
in case any clogged rubbish is found.
⚫ Floating ball is kept in a ditch of main product.
Always keep it clean to work smoothly.
Unless it does not work smoothly, it may make the liquid get out from ejector.
Photo-4
Photo-2
Switch Lever
Hexagon Socket Set Screw
(Black)φ2
You can replace with hex wrench attached
(Hex Width Across Flats: 4mm)
Floating Ball
Always keep clear to work smoothly.
6
For sucking(IN)
Hexagon Socket Set Screw
(Red)φ4
[Accessary]