B. Manual Mode
Caution: The pump is to be observed at all
times during manual mode. Prolonged
use in manual mode may result in a
shorter motor life or burnout. Set the float
switch cable into the circular groove with
the float as close to the pump as
possible. To turn on, position the float
above horizontal. The pump will now run
continuously until turned off. Turn off by
tilting the float down 30° or switching off
at the power point (GPO).
oPERAtIon
1.
The pump is now ready for use; ensure the
pump is not immersed in water deeper than
7m and that the discharge point is not higher
than 7m above the water surface.
2. Ensure the area being pumped out is large
enough to allow the float switch to move
freely and function effectively.
3. Place the pump on a flat surface and check
there are no obstructions to the suction base.
4. When the float switch is 30° higher than
horizontal or above the handle, the pump will
turn on and operate. ATTENTION: The pump
starts up as soon as the float switch reaches
start-up level. ie: Above the handle or higher
than 30°.
5. The pump will turn off when the opposite to
point 4. occurs. ie: The float switch is lower
than the handle or is lower than 30° from
horizontal. Alternatively, you can manually
turn the pump off at the mains power.
6. If you wish to use the pump down to the
minimum water depth of 50mm, the float
switch will need to be operated manually. The
pump can be manually turned "on" by lifting
the float to activate the internal switch.
NB: If you manually turn the pump off, be aware
of the location of your hose or tube. If it is at
a lower point than the pump, the water will
continue to siphon out, unless a non-return valve
(not included) is fitted to the hose or tube.
Turning On and Off
1.
Insert the plug into the mains power socket
(GPO). Avoid using extension cords as this
can lead to a voltage drop which may cause
power loss and overheating.
2. Switch on the mains power to commence
operation.
3. To cease operation, turn off the mains power.
The pump will also stop automatically once
the float switch reaches 30° below horizontal.
Hints for Operation
• To maximise pump flow use the largest
diameter hose or tube possible. Smaller
diameter hose or tube will reduce the flow
rate relative to their size. Where possible use
discharge pipes having a larger diameter than
the discharge outlet.
• Do not run the pump without water flowing
through it. This leads to increased wear and
possible burn out. Immediately unplug the
pump as soon as water supply or flow stops.
NB: The built in thermal overload protector will
automatically switch off the pump in the event of
overheating. The motor automatically switches
back on once cooled down.
MAIntEnAnCE
The pump does not require any maintenance
under normal operating conditions.
Disconnect from electrical power supply before
performing any maintenance procedures.
Cleaning the Pump Housing
Use a damp cloth to clean the outside of pump
housing. Allow to dry thoroughly before storing in
a dry location that is protected from the elements.
Cleaning the Suction Base
Hose down gently with low pressure water. Allow
to dry thoroughly before storing.
Power Cable
For all submersible pumps, a H07RN-F cable is
required. Damage to, and tampering with the
cable voids warranty.