Panasonic AG-HPX260MC Elektriksel Ayarlama - Sayfa 17
Dijital Kamera Panasonic AG-HPX260MC için çevrimiçi göz atın veya pdf Elektriksel Ayarlama indirin. Panasonic AG-HPX260MC 20 sayfaları. Memory card camera recorder p2hd
Ayrıca Panasonic AG-HPX260MC için: Servis Kılavuzu (21 sayfalar)
2-1-7. ND FILTER Compensation Adjustment
1. Set the each switch of camera recorder as follows.
● BARS button: OFF
● AUTO/MANUAL switch: MANUAL
● ZOOM switch: SERVO
● GAIN switch: L (0dB)
● ND FILTER dial: OFF
● IRIS: F5.61
● SHUTTER: 1/1000
2. Open the SYSTEM SETUP screen and set the item "SYSTEM MODE" to "1080/59.94i" (MAIN MENU >
SYSTEM SETUP > SYSTEM MODE).
3. Connect the WFM to the SDI OUT with 75ohm termination.
4. Connect the VIDEO OUT to Monitor TV.
5. Shoot a halogen lamp (8,000 to 15,000lux).
NOTE: Bring a lamp close to a lens and set illumination as 8,000 to 15,000lux.
6. Select "CAM(C)" section after start up the PC EVR software, and click "OK" button.
7. Select "Adjustment Tool" in "Tools(W)" menu, Adjustment Tool screen will appear on screen.
8. Confirm that the white level of Y signal is 70 to 90%.
9. Clicking the "Preparation->AWB" button for ND Filter Adjustment, execute AWB.
10. The message "Enable ND Filter Adjustment!" is displayed in the STATUS column on the Adjustment Tool
screen. The "Start" button becomes valid.
11. Clicking the "Start" button for ND Filter1, the camera recorder is set to ND Filter1 adjustment mode.
12. Confirm that the white level of Y signal is 70 to 90%.
13. Clicking the "Execute" button for ND Filter1, the ND Filter1(ND 1/4) adjustment is executed automatically.
14. When the adjustment is completed, the message "ND Adjustment END!" is displayed in the STATUS column
on the Adjustment Tool screen.
15. Confirm that the vector dot is located at the zero point in the WFM (vector scope).
16. Confirm that there is no colored on Monitor TV.
17. Click the "Set" button for ND Filter1 to end of ND Filter1 adjustment mode. The adjusted value is saved in
EEPROM.
Start button
Execute button
18. Clicking the "Start" button for ND Filter2, the camera recorder is set to ND Filter2 adjustment mode.
19. Confirm that the white level of Y signal is 70 to 90%.
20. Clicking the "Execute" button for ND Filter2, the ND Filter2(ND 1/16) adjustment is executed automatically.
21. When the adjustment is completed, the message "ND Adjustment END!" is displayed in the STATUS column
on the Adjustment Tool screen.
22. Confirm that the vector dot is located at the zero point in the WFM (vector scope).
23. Confirm that there is no colored on Monitor TV.
24. Click the "Set" button for ND Filter2 to end of ND Filter2 adjustment mode. The adjusted value is saved in
EEPROM.
Adjustment value
R-ch Upper/Lower, B-ch Upper/Lower
ELE-16
AWB button
Clicking the "Set" button, the adjusted
value is saved in EEPROM.