HP 10500 series Teknik Özellikler - Sayfa 12

Anahtar HP 10500 series için çevrimiçi göz atın veya pdf Teknik Özellikler indirin. HP 10500 series 20 sayfaları. Type d w/comware v7 os mpu (jh198a). product end-of-life disassembly
Ayrıca HP 10500 series için: Teknik Özellikler (42 sayfalar), Veri Sayfası (8 sayfalar), Veri Sayfası (20 sayfalar), Sökme Talimatları (3 sayfalar)

HP 10500 series Teknik Özellikler
Data sheet | HP 10500 Switch Series
Environment
Operating temperature
Operating relative humidity
Non-operating/Storage temperature
Non-operating/Storage relative humidity
Altitude
Acoustic
Electrical characteristics
Frequency
AC voltage
DC voltage
Current
Power output
Safety
Emissions
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency magnetic field
Voltage dips and interruptions
Harmonics
Flicker
Management
Notes
Services
12
HP 10504 Switch Chassis (JC613A)
32°F to 113°F (0°C to 45°C)
10% to 95%, noncondensing
-40°F to 158°F (-40°C to 70°C)
5% to 95%, noncondensing
Up to 13,123 ft (4 km)
Low-speed fan: 62.3 dB, High-speed fan: 75.5 dB
50/60 Hz
100–120/200–240 VAC
-48 to -60 VDC
16/60 A
2500 W
Notes
Based on common power supply 2,500 W (AC)
CAN/CSA 22.2 No. 60950-1; FCC Part 15, Subpart B; FDA 21 CFR
Subchapter J; RoHS Compliance; IEC 60950-1, Second Edition;
EN 60950-1:2006 + A11:2009; AS/NZS 60950-1; IEC 60825-1;
UL 60950-1, 2nd Edition; EN60825-2:2004+A1:2007
VCCI Class A; EN 55022 Class A; CISPR 22 Class A; IEC/EN 61000-
3-2; IEC/EN 61000-3-3; ICES-003 Class A; AS/NZS CISPR 22 Class A;
FCC (CFR 47, Part 15) Class A; GB9254
Directive 2004/108/EC
EN 55024:1998+ A1:2001 + A2:2003; ETSI EN 300 386 V1.3.3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
IEC 61000-4-8
EN 61000-4-11
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3
IMC—Intelligent Management Center; command-line interface;
out-of-band management (serial RS-232C); SNMP Manager; Telnet;
terminal interface (serial RS-232C); modem interface; IEEE 802.3
Ethernet MIB; Ethernet Interface MIB
These modules—JC614A, JD252A, and JD254A—are only
available using Comware v5 for the 10500. Please see an HP
representative or technical notes for details.
Refer to the HP website at hp.com/networking/services for
details on the service-level descriptions and product numbers.
For details about services and response times in your area, please
contact your local HP sales office.
HP 10508 Switch Chassis (JC612A)
32°F to 113°F (0°C to 45°C)
10% to 95%, noncondensing
-40°F to 158°F (-40°C to 70°C)
5% to 95%, noncondensing
Up to 13,123 ft (4 km)
Low-speed fan: 63 dB, High-speed fan: 75.8 dB
50/60 Hz
100–120/200–240 VAC
-48 to -60 VDC
16/60 A
2500 W
Based on common power supply 2,500 W (AC)
CAN/CSA 22.2 No. 60950-1; FCC Part 15, Subpart B; FDA 21 CFR
Subchapter J; RoHS Compliance; IEC 60950-1, Second Edition;
EN 60950-1:2006 + A11:2009; AS/NZS 60950-1; IEC 60825-1;
UL 60950-1, 2nd Edition; EN60825-2:2004+A1:2007
VCCI Class A; EN 55022 Class A; CISPR 22 Class A; IEC/EN 61000-3-2;
IEC/EN 61000-3-3; ICES-003 Class A; AS/NZS CISPR 22 Class A; FCC
(CFR 47, Part 15) Class A; GB9254
Directive 2004/108/EC
EN 55024:1998+ A1:2001 + A2:2003; ETSI EN 300 386 V1.3.3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
IEC 61000-4-8
EN 61000-4-11
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3
IMC—Intelligent Management Center; command-line interface;
out-of-band management (serial RS-232C); SNMP Manager; Telnet;
terminal interface (serial RS-232C); modem interface; IEEE 802.3
Ethernet MIB; Ethernet Interface MIB
These modules—JC614A, JD252A, and JD254A—are only
available using Comware v5 for the 10500. Please see an HP
representative or technical notes for details.
Refer to the HP website at hp.com/networking/services for
details on the service-level descriptions and product numbers.
For details about services and response times in your area, please
contact your local HP sales office.