HP StorageWorks 8/24 - SAN Switch Yayın Notu - Sayfa 25
Anahtar HP StorageWorks 8/24 - SAN Switch için çevrimiçi göz atın veya pdf Yayın Notu indirin. HP StorageWorks 8/24 - SAN Switch 30 sayfaları. Hp storageworks fabric os 6.1.2b release notes (5697-0351, march 2010)
Ayrıca HP StorageWorks 8/24 - SAN Switch için: Teknik Özellikler (20 sayfalar), Yayın Notu (29 sayfalar), Yayın Notu (32 sayfalar)
Fabric OS 6.1.0c fixes
Table 9
lists defects closed in the Fabric OS 6.1.0c firmware release.
Table 9 Fabric OS 6.1.0c closed defects
Closed defect summary
HP StorageWorks 8/40 SAN Switch running Fabric OS 6.1.0 may
generate over-temperature warnings while at ambient temperature
after booting up.
Switch allows duplicate TI Zone members to be created or added.
Out of Order frames delivered to DC SAN Director via FICON channel
from HP StorageWorks 8/40 SAN Switch attached to a storage device
(DASD).
Running supportSave from CLI or Fabric Manager for DC SAN
Director Directors takes longer than it does for other switch types.
EE monitor counters may not get updated after performing switch-
disable/switchenble or reboot.
Third party storage center application does not survive in an FCIP
network with 1% packet loss and 100 ms network latency.
"seccertutil gencsr" is not accepted in non-interactive mode if
parameter has a space in it.
EZSwitch version 6.1 can not enable Web Tools after setting the switch
IP using the IP discovery process.
The TI Zone list page displayed by Web Tools was missing some entries
on systems containing 48-port blades.
IBM XRC Emulation allows FICON Disk Control Unit paths to be activ-
ated with DPR Mode.
On HP StorageWorks 8/8, 8/24, 8/40 and 8/80 SAN Switch
models:
When normal fan activity is interrupted, the high revolution per minute
(RPM) fan rate cycle time takes 1 hour.
After changing IP address for SNMP and community level to `5`, user
will not be able to reset to default (0.0.0.0).
Some TDM devices will not work when ARB is received before EFP on
long distance links.
FICON Tape Aborted sequence due to LS Early End status for DFSORT
job.
Solution
Fixed in Fabric OS 6.1.0c
Fixed in Fabric OS 6.1.0c
Fixed in Fabric OS 6.1.0c
Fixed in Fabric OS 6.1.0c
Fixed in Fabric OS 6.1.0c
Fixed in Fabric OS 6.1.0c
Fixed in Fabric OS 6.1.0c
Fixed in Fabric OS 6.1.0c
Fixed in Fabric OS 6.1.0c
Fixed in Fabric OS 6.1.0c
Workaround: Do not mix native and
extended (FOS or USD-X/Edge)
CHPIDs in the configuration.
Fixed in Fabric OS 6.1.0c
Fixed in Fabric OS 6.1.0c
Fixed in Fabric OS 6.1.0c
Fixed in Fabric OS 6.1.0c
HP StorageWorks Fabric OS 6.1.0h release notes
25