HP surestore fc 1Gb entry switch 8B Manuel - Sayfa 38

Anahtar HP surestore fc 1Gb entry switch 8B için çevrimiçi göz atın veya pdf Manuel indirin. HP surestore fc 1Gb entry switch 8B 50 sayfaları. Fabric os procedures guide (version 3.0)

4
Displaying Error Logs and Status

Displaying the Temperature Status

To display the temperature status of a switch:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
tempShow
This command displays current temperature readings from each of the five temperature sensors
located on the main printed circuit board of the switch. The sensors are located, approximately,
one in each corner and one at the center of the PCB.

Running Diagnostic Tests on the Switch Hardware

There are several diagnostic tests you can run on a switch. These test are generally run during the
POST, each time a switch is booted up.
camtest
centralMemoryTest
cmemRetentionTest
cmiTest
crossPortTest
portLoopbackTest
sramRetentionTest
turboRamTest
statsTest
spinSilk
4-6
Fabric OS Procedures Guide