SAFETY INSTRUCTIONS FOR
CUTTING-OFF OPERATIONS
Cut-Off Machine Safety Warnings -
Kickback and Related Warnings (continued)
g. When wheel is binding or when interrupting a cut for any reason, switch off
the power tool and hold the power tool motionless until the wheel comes to
a complete stop. Never attempt to remove the wheel from the cut while the
wheel is in motion otherwise kickback may occur. Investigate and take corrective
action to eliminate the cause of wheel binding.
h. Do not restart the cutting operation in the workpiece. Let the wheel reach full
speed and carefully re-enter the cut. The wheel may bind, walk up or kickback if
the power tool is restarted in the workpiece.
i. Support panels or any oversized workpiece to minimize the risk of wheel
pinching and kickback. Large workpieces tend to sag under their own weight.
Supports must be placed under the workpiece near the line of cut and near the edge
of the workpiece on both sides of the wheel.
j. Use extra caution when making a "pocket cut" into existing walls or other
blind areas. The protruding wheel may cut gas or water pipes, electrical wiring or
objects that can cause kickback.
/10
SAFETY INSTRUCTIONS FOR
CUTTING-OFF OPERATIONS
TA BL E A – RE Q U IR ED G A UG ES F O R EX TE NSI O N CO RD S
Ampere Rating
More Than
12
WWW.DIAQUIP.CO.UK
WWW.DIAQUIP.CO.UK
Cut-Off Machine Safety Warnings - Additional Safety Rules
WARNING: Avoid cutting in the upper
quadrant of the blade, especially when
beginning the cut. This area is highly
likely to lead to kickback.
WARNING: When cutting plastics, do
not allow the plastic to melt. If the plastic
melts, it can stick to the blade, leading
to kickback.
Volts
Total length of cord in feet
110-120
25(8m)
220-240
50(15m)
Not More Than
Minimum gauge for cord (AWG)
16
14(2.5mm
50(15m)
100(30m)
150(50m)
100(30m)
150(50m)
300(100m)
2
)
12(4.0mm
2
)
Not Recommended
/11