BIOMICROBICS BioBarrier Servis Kılavuzu - Sayfa 2

Su Sistemi BIOMICROBICS BioBarrier için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. BIOMICROBICS BioBarrier 12 sayfaları.

GENERAL INFORMATION

The BioBarrier
0.5, 1.0 and 1.5 systems are certified by the NSF International/ American National Standards Institute Organizations to meet NSF/ANSI
®
Standard 40, Class 1 certification for single residence wastewater treatment devices, NSF/ANSI Standard 245 for nitrogen reduction, and NSF/ANSI
Standard 350 Class R for residential water reuse applications. All BioBarrier
you have questions regarding any Bio-Microbics products please contact us at:

DELIVERY INSPECTION

The BioBarrier
system has been carefully manufactured, checked and tested at the factory before shipment. Before and after uncrating the unit, check
®
the packaging for signs of shipping damage. If there is evidence of damage or abuse reject the shipment notify BioMicrobics, Inc. immediately at
800-753-3278 or (913) 422-0707.
THE BIOBARRIER
The BioBarrier
Membrane Bioreactor combines the activated sludge treatment process with the exceptional clarification properties of a membrane.
®
The System is installed in locally approved tanks, in a two compartment tank, or multiple tanks, with the membrane module always in the last
compartment/ tank. Primary treatment consists of sedimentation and separation of floatables and solids, and occurs in the first compartment. The
and Total Kjeldal Nitrogen.
When nitrogen removal is needed the system (The BioBarrier
at least three compartments, with exactly two compartments in the second or final tank. The first compartment or tank provides primary treatment -
sedimentation and separation of floatables and solids, and is equipped with an outlet screening device called SaniTEE
compartments must be in the same tank, and the second compartment is where denitrification takes place under anoxic conditions. The third
compartment, the aeration/membrane zone, is separated from the anoxic zone by a baffle wall between the two zones to allow nitrified waste to enter
into the anoxic area for denitrification.
Only qualified service persons should open any access port or cover on the system. Hazards such as electric shock and Infectious organisms exist in
these areas. Persons coming in contact with wastewater, must immediately wash and disinfect all exposed areas and contact your personal physician.
Failure to do so could result in severe sickness or death.
NSF Standard 350 Class R Restricted Indoor Urban Reuse Water
The BioBarrier
system has been tested under NSF Standard 350 Class R (Residential) and is
®
capable of treating residential wastewater for restricted indoor urban water reuse, which is toilet and
urinal flushing. The system design requires a holding tank and plumbing system for reuse water and
shall meet all applicable codes; have proper backflow prevention and protection against cross
connections; and is the responsibility of the local designer/installer. When the reuse water is used
for toilet and urinal flushing, additional disinfection should be considered to provide adequate
assurance in preventing microorganism growth in the treated reuse water storage tank and as
required by applicable codes. The reuse tank shall be located after the BioBarrier
tank shall also incorporate an overflow that allows excess reuse water to be dispersed in a locally
SERVICE MANUAL
1-800-753-FAST (3278) or +1 (913) 422-0707
®
SYSTEM
products are ETL certified for safety (electrical, environmental, etc.). If
®
second compartment/tank can be used to enhance the BioBarrier's
nitrogen reducing capabilities. The second compartment houses
the BioBarrier system. The BioBarrier's blower aerates the
wastewater for naturally occurring bacteria (biomass) to grow and
treat the sewage. The membrane prevents most particles from
0.5-N, 1.0-N, 1.5-N) consists of a tank with three compartments, or two tanks totaling
®
approved soil dispersal system or released into a sanitary sewer system. A potable water make up
system shall also be available to supply water when treated reuse water is not available. This potable
water make up system shall include a properly designed backflow preventer that meets all applicable
codes.
NSF Standard 350 Class R Unrestricted Outdoor Urban Reuse Water
The BioBarrier® system has been tested under NSF Standard 350 Class R (Residential) and is
system. This
®
capable of treating residential wastewater for unrestricted outdoor urban water reuse, which is
being
discharged
into
environment.
The clean water is discharged to the receiving
environment by the effluent pump. The aerator
also helps limit the rate of fouling on the
membrane sheets. This is a continuous
process provided the biomass is supplied with
waste (food) and air in a suitable environment.
A vent pipe allows for venting of non-harmful
by-products created by the process. The entire
process produces effluent with very low levels
of bacteria, organic matter (BOD), solids (TSS)
. The second and third
®
the
receiving