Bionaire BAP1550 Kullanım Kılavuzu - Sayfa 2
Hava Temizleyici Bionaire BAP1550 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Bionaire BAP1550 2 sayfaları. Tower air purifier with permanent filters
Ayrıca Bionaire BAP1550 için: Kullanım Kılavuzu (2 sayfalar)

BAP1550-IUK_07EM1.qxd
4/25/07
20:46
Page 5
A
B
C
D
E
D
B
K
B
L
J
C
I
Fig. 2
Fig. 3
mechanical functions of this unit. If the unit
U.K. and IRELAND
becomes damaged return to the place of
Fig. 1
purchase or phone the helpline number on
the back of this leaflet.
PLEASE READ AND SAVE THESE
• If the supply cord or plug is damaged, it must
IMPORTANT INSTRUCTIONS.
be replaced by the manufacturer or its service
With proper care and use, this Bionaire
®
agent or a similarly qualified person in order
air purifier will give you fresh, clean air
E
to avoid hazard.
for many years.
• The air purifier contains no user serviceable
NOTE: Before reading these instructions, please
parts and should the product suffer damage
view the corresponding illustrations.
or breakdown it must be returned to the
manufacturer or its service agent.
DESCRIPTIONS (SEE FIG. 1 & FIG. 1-A)
• Should the air purifier stop working, first check the
A. Power Light
fuse in the plug (UK only) or fuse/circuit breaker at
B. Speed Control
the distribution board is operating, before
contacting the manufacturer or service agent.
C.Ioniser Control
• The ioniser may cause a static charge to build
D.Filter Indicator Light
up on the air output grill. A static charge may
E. Ioniser Light
F
be felt if the unit is not properly grounded. To
F. Washable Foam Pre-filter
avoid a static charge, plug the unit into a
G.Inlet Grill
grounded outlet, or properly install a ground
adaptor. The static shock will not occur if the
H.Permanent HEPA filters (2 pcs)
ioniser is off.
I. Filtered Air Outlet
• This appliance is not intended for use by
J. Power Button
persons (including children) with reduced
K. Infrared
physical, sensory or mental capabilities, or lack
L. Operation Indicator Light
of experience and knowledge, unless they have
G
been given supervision or instruction concerning
SAFETY PRECAUTION
use of the appliance by a person responsible for
Carefully read and retain all instructions before
their safety. Children should be supervised to
using the air purifier.
ensure that they do not play with the appliance.
• To avoid fire or shock hazard, check that the
HOW THE AIR PURIFIER WORKS
voltage on the product corresponds to your
electricity supply and plug directly into an
Dirty, dust laden air is drawn through the back of
electrical outlet.
the air purifier and through the multi-stage
filtration system.
• Keep cord out of heavy traffic areas and to
avoid fire hazard, never put the cord under
The permanent HEPA filter entraps 99% of all
rugs, or near any heat source.
smaller visible and non-visible particles down to
• Carefully discard any plastic wrapping that
2 microns in size.
H
was used for the packaging. If the filter is
covered by a bag when shipped, remove
IONISER
plastic bag before use.
Your Bionaire
controlled ioniser, which when turned on,
• Do not use the air purifier outside.
releases negative ions into the outgoing filtered
• Do not place the unit near any heat source or
air. Ions are tiny particles that carry either a
in direct sunlight.
positive or negative charge. These ions exist
• Always unplug the air purifier before moving it,
naturally all around us in the air, water and
Fig. 4
opening the grill, changing the filters, cleaning the
ground. Both positive and negative ions are
air purifier or whenever it is not in use.
colourless, odourless and completely harmless.
• Do not use in or around water or any other
Negative ions help the air purification process
liquids. Do not attempt to wash the unit under
by attaching themselves to very small airborne
running water.
particles in the room. These particles take on a
• Use appliance only for intended household
negative charge and may join with positively
use as described in this manual.
charged particles, such as dust, pollen, smoke
• Ensure that all air openings are not restricted
and pet dander to form larger particles that are
or covered in any way.
then more readily captured by the filter system,
or they may be attracted to positively charged
• Do not place anything on top of the unit.
surfaces like walls or floors.
• Never insert any object into any openings.
You may also note, after extended use, that dust
• Do not use the air purifier if any part is
may have collected around the grills or front panel.
missing or damaged in any way.
This is from the ionisation effect caused by the
• Do not attempt to repair or adjust any
negative ions exiting from the air outlet.This dust
does not come from the air output, but is drawn out
of the uncleaned air going past the air outlet.
This is additional evidence of the air cleaning
effectiveness of negative ions. The dust can be easily
removed with a clean, dampened cloth or soft brush.
NOTE: it is important to clean the permanent
HEPA filters at recommended intervals. Using the
ioniser in conjunction with dirty filters may result in
dirty particles exiting the air purifier and being
attracted to walls, carpets, furniture and other
household objects. These dirty particles may prove
very difficult to remove.
PRE-OPERATING INSTRUCTIONS
1. After removing the unit from the box, remove
the plastic covering from the unit.
2. Select a firm level place where there are no
obstructions to the air inlet (rear grill) or
filtered air outlet.
3. Remove the inlet grill by pulling the grill
towards you.
4. Remove both permanent HEPA filters by
gripping on both sides and pulling forward.
5. The filter clip can only be attached to the
hang tabs on the filter one way (see Fig. 2).
The filter clip should easily slide onto the filter
hang tabs. Do not use force whilst attaching
the filter clip to the filter. Align the clip on the
permanent HEPA filter with the rails on the
inside of the unit.(see Fig. 3)
NOTE: The pleated material and rubber gasket
should be facing towards the unit when applied.
6. Replace the inlet grill by sliding back on to the
unit. Make sure that it snaps securely into
position (the grill only goes on one way).
NOTE: Do not point outlet towards wall.
OPERATING INSTRUCTIONS
Your remote control requires (2) AAA batteries
(not included) for operation. To install the
®
Air Purifier has an independently
batteries, simply depress and slide the back of
the remote control with your thumb on the arrow
indentation. Insert batteries according to the
diagram shown inside and replace cover. Remove
batteries before discarding the remote control.
• DO NOT mix old and new batteries.
• DO NOT mix alkaline, standard (carbon-zinc)
or rechargeable (nickel-cadmium) batteries.
1. Plug into a suitable electrical outlet.
2. Press the power button (
) on the control
panel or the remote control. The unit will turn
on high only the first time the unit is turned
on. All other times it is turned on, the unit
remembers the last speed selected and will
turn on at that speed, and the power light will
illuminate letting you know the power is on.
3. You can then select the desired speed
setting. This air cleaner has three speed
settings. You can select from HIGH (
MEDIUM(
), or LOW (
) by pushing the
5. This model utilises a hang tab and filter clips to
insure that the filter is properly in place. Before
desired operating speed button on the control
replacing the permanent HEPA filter make sure
panel or the remote control.
that the hang tab is securely in place.
4. To release negative ions into the filtered air,
6. Align the clips on the side of your permanent
press the ioniser button (
) to either on the
HEPA filter with the rails on the inside of the
control panel or the remote control and the
light will illuminate.
unit. Gently slide the filter onto the rails.
5. The ioniser will not work unless the unit is running.
7. The filter clip should easily slide onto the filter
hang tabs. Do not use force while attaching the
6. For optimum air filtration, it is recommended to
filter clip to the filter. Align the clip on the side
operate the air purifier continuously. Its rugged
of your permanent HEPA filter with the rails on
motor is designed to give many years of service.
the inside of the unit. (see Fig. 2 and 3)
7. For continuous use it is recommended to operate
NOTE: The pleated material and rubber gasket
the air purifier at the Medium (
) setting. For
should be facing towards the unit when applied.
quieter operation or use in a bedroom, select the
Low ( ) setting. When high levels of air pollution
8. Replace the inlet grill by sliding back on to the
unit. Make sure that it snaps securely into
are present, select the HI (
) setting to quickly
position (the grill only goes on one way).
circulate clean filtered air.
NOTE: Do not point outlet towards wall.
CLEANING AND MAINTENANCE
9. The filter life indicator (
1. Turn the air purifier off and unplug it before
once the permanent filters have been cleaned.
cleaning.
Reset indicator by pressing the power button
2. The outside of the air purifier can be cleaned
(
) on the control panel for 2 seconds.
with a soft, clean dampened cloth.
Filter Life – The filter has been designed to never
3. The rear air inlet grill can be removed and
need replacement, however, it does need servicing.
washed in warm soapy water (not dishwasher
We recommend that under normal conditions of
safe). Dry before replacing in the unit.
continuous use, the filters should be cleaned at least
every 3 months to help maintain optimal performance.
4. The filtered air outlet can be cleaned of dust
with a small, soft brush.
Should the filter become damaged during
cleaning replacements are available by calling
5. If you wish to clean the inside of the air purifier,
0870 759 9000.
please only use a dry, soft cloth to wipe it down.
PERMANENT HEPA filter Filters
PERMANENT HEPA FILTER CLEANING
(Usage: 2 pcs)
Filter Indicator Light (
) - Your air purifier has
an indicator light that illuminates when it is time
TROUBLESHOOTING
to clean the permanent HEPA filters.
Problem
1. Every few weeks check the condition of the
Unit will not
pre-filter.
operate.
2. Remove the inlet grill. If the foam pre-filter has
collected a noticeable amount of dust, remove it
from the inlet of the grill and wash it in warm soapy
water. Rinse and dry the pre-filter thoroughly
before replacing it in the inlet of the grill.
3. With the inlet grill removed, check the
Decreased
air flow.
condition of your permanent HEPA filters. If
the filters are dirty, remove them by gripping
on both sides and pulling forward.
4. To clean the permanent HEPA filters use a
crevice tool or brush attachment with your
vacuum cleaner. Run the attachment along the
inlet and outlet side of the filter trying to clean
Noise
between the pleated filter layers. (see Fig. 4).
NOTE: Vacuuming will restore performance
of the permanent HEPA filter however, the
Holmes Products (Europe) Ltd reserves the right
filter may appear stained. This is normal and
to change or modify any specifications without
does not affect performance in any way.
notice.
DO NOT USE WATER OR ANY OTHER
For U.K. and Ireland only:
HOUSEHOLD CLEANERS OR
If the plug is not suitable for the socket outlets in
DETERGENTS TO CLEAN THE
your home, it can be removed and replaced by
PERMANENT HEPA FILTERs.
),
a plug of the correct type. Please refer to
"Installation of a plug" below.
Installation of a plug Applicable to
U.K. and Ireland.
WARNING - THIS APPLIANCE MUST BE
EARTHED
The wires in the mains lead are coloured as such:
GREEN AND YELLOW
- EARTH
BROWN
- LIVE
BLUE
- NEUTRAL
Please note that the colour of these mains wires
may not correspond with the colour markings
that identify the terminals in your plug.
Please proceed as follows:
The wire which is coloured GREEN AND YELLOW
must be connected to the terminal which is marked
with the letter 'E' or by the earth symbol
or
coloured GREEN AND YELLOW.
) must be reset
The BROWN coloured wire must be connected
to the terminal, which is marked with the letter
"L" or is coloured RED.
The BLUE coloured wire must be connected to
the terminal, which is marked with the letter "N"
or is coloured BLACK.
Solution
Check to make sure the unit is
NOTE: If the terminals in the plug are not marked
plugged in.
or if you are unsure or in doubt about the installation
Check to make sure the unit is on
of the plug please contact a qualified electrician.
by pressing the power button.
If a 13A 3-pin plug is fitted, it must be an ASTA
Make sure the filters are properly
approved plug, conforming to BS1363 standard.
installed and firmly close the door.
Replacement 3A fuses must be BSI or ASTA
If the Filter Life Indicator (
) is
BS1362 approved.
red, the permanent HEPA filter
should be cleaned.
GUARANTEE
PLEASE KEEP YOUR RECEIPT AS THIS WILL
Check the filter to make sure
they are in good condition.
BE REQUIRED FOR ANY CLAIMS UNDER
Check to ensure nothing is blocking
THIS GUARANTEE.
the air inlet and filtered air outlet.
• This appliance is guaranteed for 2 years.
• In the unlikely event of breakdown from a
Make sure filter bags are
manufacturing related fault, please return it to
removed if present.
the place of purchase, with your till receipt
and a copy of this guarantee.
• The rights and benefits under this guarantee
are additional to your statutory rights which
are not affected by this guarantee.
• Holmes Products (Europe) Ltd undertakes
within the specifiied period, to repair or replace free
of charge, any part of the appliance found to be
defective from a manufacturing fault provided that: