F E AT U R E S - O P E R AT I O N S
"High speed" level when the ambient temperature is
higher or equal to 32ºC that detected by the
temperature sensor built in the unit.
4. Press "TIMER" (
) to select the desired hour of
automatic shut off at 1H, 2H, 4H, 8H.
a. Press "TIMER" (
automatic shut off, the related indicator light will
illuminate. The unit will continue operating without
setting timer, the indicator light of automatic shut
off will not illuminate.
b. The timer setting will be calculated automatically
and the indicator light of automatic shut off will
indicate the hours remaining.
c. The unit will switch off automatically & stop
working when the timer setting run out.
5. Press "HUMIDITY" (
relative humidity at 40% RH, 60% RH, 80% RH.
a. Press "HUMIDITY" (
ambient relative humidity at 40% RH, Press
"HUMIDITY" (
) twice to select the desired
ambient relative humidity at 60% RH, Press
"HUMIDITY" (
) three times to select the desired
ambient relative humidity at 80% RH. Press
"HUMIDITY" (
) four times to select the constant
dehumidifying function.
b. The unit will stop dehumidifying automatically
when the ambient relative humidity is 2% RH
lower than the setting %RH, the indicator light of
"Power On" will turn off. The fan blower will
operate at "Low speed" level.
The unit will start to dehumidify automatically
when the ambient relative humidify is 2% RH
higher than the setting %RH, the indicator light of
"Power On" will illuminate. The fan blower keeps
running as per the setting level.
Automatic Defrosting ( )
1. When the temperature sensor on the copper pipe
detects that the surface of the evaporator dropped
down to -1ºC, the auto defrost function starts up.
2. The frost thawing and the temperature sensor detects
the surface of the evaporator is higher than 3ºC,
defrost function will stop and dehumidifying function
will start. When defrosting, indicator light of defrost
(
) will illuminate and the indicator light of
dehumidifying will turn off.
3. When Defrost (
) icon is displayed on Control
) to select the desired hour of
) to select the desired ambient
) once to select the desired
Panel, the compressor is shut off, fan runs at high
speed. When Dehumidifying icon is displayed on
Control Panel, the compressor will work, and fan runs
at original set speed.
Water Full Protection (
When condensed water is full, buzzer will alarm 10 times.
In about 5 seconds, the Water Full icon (
on LCD screen, all other icons are disappeared. The water
reservoir must be removed to empty (see Figure 3) and
reinstalled before the unit operates again. The interval of
dehumidifying takes about 3 minutes, as the compressor
is under protection.
AUTOMATIC SHUT-OFF PROTECTION
Processions Of Abnormal Compressor
During the operation, any malfunction forced compressor
failed, resulting compressor shut off, it takes 3 minutes to
reset.
After removing the water reservoir and intend to reset
the operation, it takes about 3 minutes to start the unit
again for protection purpose. To speed up, you may
unplug to reset the unit.
Protection Of Extremely Low & High
Figure 3
Remove Water Reservoir
)
) is displayed