Dickson TR220 Manuel - Sayfa 2

Veri Kaydediciler Dickson TR220 için çevrimiçi göz atın veya pdf Manuel indirin. Dickson TR220 2 sayfaları. Push to start logger operation

Dickson TR220 Manuel
Specifications
Operating Range (unit only)
Internal Temperature Sensor
Internal Temperature Sensor
Internal Temperature Accuracy
Internal Temperature Accuracy
External Temperature Sensor
External Temperature Sensor
External Temperature Range
External Temperature Range
External Temperature Accuracy
External Temperature Accuracy
R/H Sensor Type
R/H Sensor Type
% RH Accuracy
Storage Capacity
Storage Capacity
Logger Resolution
Logger Resolution
Display Resolution
Troubleshooting
No communication
• Verify that you have the correct version of Dickson
software installed on your PC. Version 7.2 or higher is
required for models SR200 and TR220.
• Verify that the correct COM port is selected: From
the main DicksonWare™ screen, click on Logger
then Communication, a black dot will appear next
to the selected COM port. You may need to select a
different COM port. Should you get an error message
stating that "Device Is Already Open", this could mean
that you have the proper COM port selected, but
another device, or it's software, has it allocated. Palm
pilots, for example, will cause this problem, in which
case the port is not actually "Available" and you may
have to disable that device.
• You may need to relocate the download cable to
another serial port on the back of the PC and possibly
try changing the COM port again in DicksonWare™.
• If communication has not been established with the
previous steps, you may need to open the logger,
remove the battery, reinsert it and then try all COM
port and cable combinations again.
• If possible, try another PC
Indicator
There is a red indicator located to the right of the display.
This indicator will flash every 10 seconds ONLY when the
unit is sampling and operating properly. If the indicator is
Factory Service and Returns
Contact the factory for a Return Authorization (RA)
Number before returning any instrument. The model
number, serial number and a purchase order number will
be requested before an RA number is issued.
DICKSON
www.dicksonweb.com
930 South Westwood Avenue • Addison, IL 60101-4917
Telephone: 630-543-3747 • Fax: 630-543-0498
SR200
-40 to +176°F
(non-condensing)
(non-condensing)
Digital Sensor
Digital Sensor
±1.8°F (14 to 158°F)
N/A
N/A
N/A
N/A
N/A
32,512
0.1°F
N/A
not flashing, please verify the following:
• The logger memory may be full; download the data
and clear the memory.
• Sampling may not be activated. To start sampling
clear the memory.
• Condensation may have formed on the unit. Place unit
in a warm dry environment for 24 hrs. Clear memory
and try again.
These loggers are designed for use in a non-condensing
environment. If the environment creates condensation,
try placing the unit (temperature only models) in a small
sealed plastic bag to protect it from condensation.
Battery
The battery will operate the logger for 1.5 years at room
temperature. Operation of the logger at the temperature
extremes, in real-time mode for prolonged periods, or
sample intervals of less than a minute, will significantly
reduce battery life. To replace the battery, simply remove
the 4 screws in the back of the logger, replace the
battery, and reassemble. Make sure that you place the
positive (+) pole towards the + sign on the circuit board.
The Battery Level Monitor on the Setup screen displays
the battery voltage and a Low Battery Warning when
replacement is needed.
Please visit www.dicksonweb.com for complete
troubleshooting guide or call (630) 543-3747.
NOTE: Dickson shall not be liable for consequential or
incidental damages resulting from failure or malfunction
of its products.
rev. 08/04
TR220
-40 to +176°F
(non-condensing)
(non-condensing)
Digital Sensor
Digital Sensor
±1.8°F (14 to 158°F)
N/A
N/A
N/A
Capacitive / Monolithic
Capacitive / Monolithic
±2% @ 77°F
0 to 95%
32,512
0.1°F
N/A