Alpha IP FAL 21001-06 Manuel - Sayfa 14
Kablosuz Erişim Noktası Alpha IP FAL 21001-06 için çevrimiçi göz atın veya pdf Manuel indirin. Alpha IP FAL 21001-06 17 sayfaları.
Configuration
UnP2:
Parameters
Duration of valve pro-
tection function
Time interval for valve
protection function:
ChAn:
Parameters
Pump lead time
(only available for
Ch01)
Duration of pump
protection function
(only available for
Ch01)
Pump follow-up time
(only available for
Ch01)
Minimum floor tem-
perature in connection
with a floor tempera-
ture sensor
Humidity limit
14
Index
Value
P007
128
129
...
133 (default)
...
138
P051
224
225
...
238 (default)
...
251
252
Index
Value
P006
128
129
130 (default)
...
147
148
P007
128
129 (default)
...
137
138
P008
128
129
130 (default)
...
147
148
P045
10
11
...
38 (default)
...
59
60
P050
40
...
80
168
...
188 (default)
...
208
Meaning
0 minutes
1 minute
...
5 minutes
...
10 minutes
0 days
1 day
...
14 days
...
27 days
28 days
Meaning
0 minutes
1 minute
2 minutes
...
19 minutes
20 minutes
0 minutes
1 minute
...
9 minutes
10 minutes
0 minutes
1 minute
2 minutes
...
19 minutes
20 minutes
5.0 °C
5.5 °C
...
19.0 °C
...
29.5°C
30.0°C
40 %; inactive
...
80 %; inactive
40 %; active
...
60 %; active
...
80 %; active