Epcom PROAUDIO SF-2240UC Kullanım Kılavuzu - Sayfa 10
Amplifikatör Epcom PROAUDIO SF-2240UC için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Epcom PROAUDIO SF-2240UC 20 sayfaları. Class d power amplifier
5. OPERATION ILLUSTRATION
7. Speaker Connection
Before turning on the device, please carefully confirm that the load is constant-voltage or
constant-impedance speakers and set the amplifier to the corresponding output mode. It is
forbidden to switch the constant voltage and constant impedance state arbitrarily when the
power is on.
Constant voltage mode: Turn the switches corresponding to CH1/CH2: 4-16Ω to OFF.
Constant impedance mode: Turn the switches corresponding to CH1/CH2: 4-16Ω to ON.
The operation method is as follows:
① When the 100V and 4-16Ω speaker output
mode selection switch is set to the 100V
position, as shown in the figure below:
100V/4-16Ω
OUTPUT
CH2
CH1
-
-
+
+
SPK+
100V voltage speaker
8. Audio source priority
EMC >MUTE >REMOTE MIC >INPUT1-4 >LINE1-2。
9. Method of making network connection line
1 2 3 4 5 6
A
A: 1 Blue 2 White-Blue 3 Brown 4 White-Brown 5 Orange 6 White-Orange 7 Green 8 White-Green
B: 1 Blue 2 White-Blue 3 Brown 4 White-Brown 5 Orange 6 White-Orange 7 Green 8 White-Green
Note: The color of cable is not specified. A=B is satisfied.
◆ Remote micrphone cable sequence:
1 MIC485-N
5 GND
2 MIC485-P
6 +24V
3 +24V
7 MIC INPUT+
4 GND
8 MIC INPUT-
1 2
DIP
SPK-
7 8
②When the 100V and 4-16Ω speaker output
mode selection switch is set to the 4-16Ω
position, as shown in the figure below:
100V/4-16Ω
OUTPUT
CH2
-
+
+
SPK+
constant impedance speaker
4Ω
1 2 3 4 5 6 7 8
◆ Remote volume control cable sequence:
1 PAN485-N
5 GND
2 PAN485-P
6 +24V
3 +24V
7 GND
4 GND
8 GND
10
CH1
-
1 2
DIP
SPK-
B