※The default value can be changed according to the user requirement.
4)Time Control
Control the load on/off time by setting the real-time clock.
5) Intelligent Power Mode
When the battery voltage is lower than "Under Voltage Warning Recover Voltage (UVWR
adjustable)", the intelligent power mode is enabled; at this time, the LED current
percentage will be automatically reduced in linear with the voltage drop of battery. When
the battery voltage is lower than "Under Voltage Warning Voltage (UVW adjustable)", a
minimum LED current percentage (default 2%, adjustable) will be output. In addition, when
the battery voltage is higher than UVWR, the controller will exit the intelligent power mode.
NOTE:The load is ON when the controller power on 1seconds. After 1
seconds it will restore to set working mode.
NOTE:In the mode of Light ON/OFF and Light ON/Timer, the load is
turned on after 10Min. delay,the delay time can be set.
6. Setting Operation
There are two methods that it can realize controller work
mode and parameters through IR function:
1) 2.4G Remote Controller—RC11
This method can realize one-key setting operation which is
suitable for bulk quantity products setting or applied in the
projects.
2) Super Parameter Programmer—FC02
NOTE: Please refer to the user manual of handheld
device.
7. Protection
Protection
Conditions
PV Reverse
When the battery is correct connecting, the
Polarity
PV can be reversed.
Battery Reverse
When the PV is not connecting, the battery
Polarity
can be reversed.
Battery Over
The battery voltage reaches to the OVD
Voltage
Battery Over
The battery voltage reaches to the LVD
Discharge
Battery
Temperature sensor is higher than 65℃
Overheating
Temperature sensor is less than 55℃
Temperature sensor is less than the low-
Lithium battery
temperature value
Low Temperature
★
Temperature sensor is higher than the low-
temperature value
Load current ≥2.5 times rated current
One short circuit, the output is OFF 5s;
Two short circuits, the output is OFF 10s;
Load Short
Three short circuits, the output is OFF 15s;
Circuit
Four short circuits, the output is OFF 20s;
Five short circuits, the output is OFF 25s;
Six short circuits, the output is OFF
Max. load voltage≥68V
One open circuit, the output is OFF 5s;
Two open t circuits, the output is OFF 10s;
Load Open
Three open circuits, the output is OFF 15s;
Circuit(Load over
Four open circuits, the output is OFF 20s;
voltage)
Five open circuits, the output is OFF 25s;
Six open circuits, the output is OFF5s;
Seven open circuits, the output is OFF5s
★Warning: If selecting a lithium battery, it must be set at low-temperature
value(LTV) according to the charging/discharging temperature of lithium
battery; otherwise, the lithium battery will be damaged.
8. Troubleshooting
Faults
Possible reasons
Charging LED
indicator off during
PV
the daytime when
array disconnection
sunshine falls on PV
modules properly
Min.9V can start up the
No LED indicator
controller.
Battery LED
indicator green Fast
Battery over voltage
Flashing
Battery
Battery LED
indicator red
over discharged
Battery Status LED
indicator red
Battery Overheating
flashing
All the LED indicator
System voltage error
BEIJING EPSOLAR TECHNOLOGY CO., LTD.
2H
0H
00:00—23:59H
50%
0%
0—100%
0H
0H
00:00—23:59H
0%
0%
0—100%
0H
2H
00:00—23:59H
0%
100%
0—100%
Status
The controller is not
damage
Stop charging
Stop discharging
Output is OFF
Output is ON
Stop charging or
discharge
Begin charging or
discharge
Output is OFF
Clear the fault:
Restart the controller
or wait for one
night-day cycle
(night time>3 hours).
Output is OFF
(Cycle to perform)
Troubleshooting
Confirm that PV and battery wire
connections are correct and tight
Measure battery voltage with
multi-meter. Min.9V can start up the
controller.
①Disconnect the solar array and
measure the battery voltage whether
is too high; ②Change the controller;
③ Change the battery
When the battery voltage is restored
to or above setpoint (low voltage
①
reconnect voltage), the load work
The controller will automatically stop
working. When the temperature is
below 50 º C, the controller will resume
working.
Check whether the battery voltage
3
Tel:+86-10-82894112 / 82894962 Website:www.epsolarpv.com/www.epever.com
flashing(battery red
indicator flashing)
①Unreliable wiring,
connection fails.
②The loading mode is
Power on normally,
wrong
③The controller does
the load is off
not match with the LED
light.
④Output short circuit
The controller does not
match with the LED
light source. This
The dimming
product is a step-up
function is invalid
current control, if the
input voltage is lower
than the rated voltage,
it is not working.
①When the battery is over-discharged, the battery indicator will be red, and the load will be
off all the time before the voltage is more than the Low Voltage Reconnect Voltage (LVRV). In
order to judge the system is normal or not, firstly measuring the battery voltage whether is
more than LVRV, if not, restarting the controller to detect the load whether it is normal.
WARNING: The LVRV can be set, but must be more careful that it maybe
damages the battery if the LVRV is set too low.
9. Technical Specifications
Item
LS101240LPLW
Nominal system
voltage
Rated charge current
Max. PV open circuit
voltage
Battery input voltage range
Max. output power
40W
Max. output Current
2.6A
Output voltage range
Load open circuit voltage
Maximum output efficiency
Output current
control accuracy
Lead-acid battery: Sealed(default)/Gel/Flooded/User
Battery Type
Lithium battery:LiFePO4/Li-NiCoMn/User
Equalization Voltage▼ Sealed:14.6V; Flooded:14.8V;User:9-17V
Boost Voltage▼
Sealed:14.4V;Gel:14.2V;Flooded:14.6V;User:9-17V
Float Voltage▼
Sealed/Gel/Flooded:13.8V;User:9-17V
UVWR▼
Sealed/Gel/Flooded:12.2V;User:9-17V
UVW▼
Sealed/Gel/Flooded:12.0V;User:9-17V
Low Voltage
Sealed/Gel/Flooded:12.6V:User:9-17V
Recover Voltage▼
Low Voltage
Sealed/Gel/Flooded:11.1V:User:9-17V
Disconnect Voltage▼
Boost Voltage▼
LiFePO4(4s):14.5V/Li-NiCoMn(3s):12.5V/User:9-17V
UVWR▼
LiFePO4(4s):12.8V/Li-NiCoMn(3s):12.2V/User:9-17V
UVW▼
LiFePO4(4s):12.0V/Li-NiCoMn(3s):10.5V/User:9-17V
Low Voltage
LiFePO4(4s):12.8V/Li-NiCoMn(3s):10.5V/User:9-17V
Reconnect Voltage▼
Low Voltage
LiFePO4(4s):11.1V/Li-NiCoMn(3s):9.3V/User:9-17V
Disconnect Voltage▼
Self-consumption
Charge Circuit Voltage
Drop
Communication way
Communication distance
Working environment
temperature
Enclosure
Overall dimension(mm)
87x58x22.8
Mounting dimension(mm)
Mounting hole size(mm)
2
Power cable(AWG/mm
)
0.17kg
Net weight
◆ The controller is not recognized system voltage and no temperature
compensation when the battery connects the lithium battery.
▼The parameters are 12V system at 25 º C, please double the values in 24V system.
10. Disclaimer
This warranty does not apply under the following conditions:
Damage from improper use or use in an unsuitable environment.
PV or load current, voltage or power exceeding the rated value of the controller.
The controller is working temperature exceeds the limit working environment
temperature.
User disassembly or attempted repair the controller without permission.
The controller is damaged due to natural elements such as lighting.
The controller is damaged during transportation and shipment.
Any changes without prior notice!
matches the controller working
voltage. Please change to a suitable
battery or reset the working voltage
①Check the connecting cables
②Check the load mode and
parameter
③The voltage of LED-light source is
not in the output voltage range of
controller
④Check the connecting cables and
LED light source
①Replace the LED light
②Reduce system rated voltage grade
and replace the product model
For example, 24V system change to
12V system, and replace the
corresponding controller.
LS101260LPLW
LS102460LPLW
12VDC
12/24VDC◆ or Auto
10A
10A
30V
50V
9~16V
9~32V
30W/12V
60W
60W/24V
4.0A
2.0A
(Max. Battery Voltage +2V)~60V
60V
96%
≤30mA
≤19mA(12V);≤35mA(24V)
≤0.17V
2.4G
≤20m
-40℃~+55℃
IP68(1.5m,72h)
87x63x24.8
108.5x118x25.6
80
Φ4
PV/BAT:14/2.5
LOAD:18/1.0
0.20kg
Version number:V1.0
4
LS2024120LPLW
20A
60W/12V
120W/24V
4.0A
100.5 x 76
Φ5
PV/BAT:12/4.0
LOAD:18/1.0
0.40kg