Epever LandStar LS102480GPLI Hızlı Kılavuz - Sayfa 2
Kontrolör Epever LandStar LS102480GPLI için çevrimiçi göz atın veya pdf Hızlı Kılavuz indirin. Epever LandStar LS102480GPLI 2 sayfaları. Solar charge controller with built in led driver of step-down voltage
Item
Mode1
LED Rated Current
2H
Time1
LED Rated Current Percentage
100%
2H
Time2
LED Rated Current Percentage
80%
Time3
2H
LED Rated Current Percentage
50%
4) Real-time Control
Control the load ON/OFF time through setting real-time clock.
5)Battery under voltage control
When the battery under voltage, the controller will reduce the LED rated
current percentage for charging automatically. Return to normal mode when
recovery from under voltage.
NOTE:The load is ON when the controller power on 10seconds. After 10
seconds it will restore to set working mode.
NOTE:In the mode of Light ON/OFF and Light ON/Timer, the Load is
turned on after 10Min. delay,the delay time can be set.
8. Protection
Protection
Battery straight polarity and PV reverse
PV Reverse Polarity①
polarity
Battery Reverse
LED lights straight polarity and battery
reverse polarity
Polarity②
Battery Over Voltage
The battery voltage reaches to the OVD
Battery Over Discharge
The battery voltage reaches to the LVD
Temperature sensor is higher than 65℃
Battery Overheating
Temperature sensor is less than55℃
Load current ≥4 times rated current
Load Short Circuit
Clear the fault: Restart the controller or
(5 times reconnect
wait for one night-day cycle (night time>3
load)
hours).
①WARNING: The controller will be damaged when battery reverse polarity
and PV reverse polarity!
②WARNING: The controller will be damaged when battery reverse polarity
and PV straight polarity!
9. Troubleshooting
Faults
Possible reasons
Charging LED
indicator(or LCD)
off during daytime
PV array
when sunshine falls
disconnection
on solar modules
properly
Wire connection is
correct, the
Battery voltage
controller is not
maybe less than 8V
working
Battery LED
indicator green fast
Battery over voltage
flashing
Battery LED
Battery over
indicator red color
discharged
Battery LED
indicator red slowly
Battery Overheating
flashing
①The connecting
wires are error or
virtually connected
②Load mode is not
Powering on
normally, the LED
appropriate.③This
is off
controller does not
match with the LED
light.④Output short
circuit.
The controller does
The dimming
not match with the
function is invalid
LED light source.
10. Technical Specifications
Item
Nominal system voltage
Rated charge current
BEIJING EPSOLAR TECHNOLOGY CO., LTD.
Default
Range
Mode2
LS102480GPLI:0-4A(12V/24V)
0.35A
LS2024100GPLI:0-5A(12V/24V)
1H
00:00—23:59H
100%
0—100%
1H
00:00—23:59H
50%
0—100%
2H
00:00—23:59H
100%
0—100%
Conditions
The controller is
not damage
Stop charging
stop discharging
Output is OFF
Output is ON
Output is OFF
Output is ON
Troubleshooting
Confirm that PV and battery
wire connections are correct
and tight
Measure battery voltage with
the multi-meter. Min.8V can
start up the controller
Check if battery voltage is
higher than OVD, and
disconnect the PV
When the battery voltage is
restored to or above LVR point
(low voltage reconnect
voltage), the load will recover
The controller will
automatically turn the system
off. But while the temperature
decline to be below 55 º C, the
controller will resume.
①Check the connecting cable.
② Check the load's mode and
parameters.③The voltage of
LED light is not within the
output voltage range of
controller.④Check the
connecting cables and LED
light.
This product is a step-down
voltage control, If input voltage
is higher than the Load output
voltage, it is not working.
Replace the LED light.
LS102480GPLI
LS2024100GPLI
12/24VDC Auto
10A
20A
3
Tel: +86-10-82894112 / 82894962
Max. PV open circuit
voltage
Battery input voltage
range
Max. output power
Max. output current
Max. output voltage
Max. output efficiency
Output current control
accuracy
Battery Type
Communication
Communication distance
Communication angle
Self-consumption
Charge Circuit Voltage
Drop
Temperature
compensation
coefficient
Working environment
temperature
Enclosure
Status
Overall dimension
Mounting dimension
Mounting hole size
Power cable
Net weight
Battery Voltage Control Parameters
Below parameters are in 12V system at 25 º C, please double the values in
24V system
Battery Type
Over Voltage Disconnect
Voltage
Charging Limit Voltage
Over Voltage Reconnect
Voltage
Equalize Charging
Voltage
Boost Charging Voltage
Float Charging Voltage
Boost Reconnect
Charging Voltage
Low Voltage Reconnect
Voltage
Under Voltage Warning
Reconnect Voltage
Under Voltage Warning
Voltage
Low Voltage Disconnect
Voltage
Discharging Limit Voltage
Equalize Duration
Boost Duration
NOTE:1) The default battery type is Sealed, For Sealed, Gel, Flooded
battery type, the voltage point is fixed, unable to be modified. The
adjusting range of equalize duration is 0 to180min and boost duration is
10 to180min.
2) User type is the user defined battery type. The default value is the
same as sealed type. When modify it, please follow the below logistic
relation:
a ) Over Voltage Disconnect Voltage>Charging Limit Voltage ≥Equalize
Charging Voltage ≥Boost Charging Voltage ≥ Float Charging Voltage >
Boost Reconnect Charging Voltage.
b ) Over Voltage Disconnect Voltage>Over Voltage Reconnect Voltage.
c) Low Voltage Reconnect Voltage>Low Voltage Disconnect Voltage ≥
Discharging Limit Voltage.
d ) Under Voltage Warning Reconnect Voltage>Under Voltage Warning
Voltage ≥ Discharging Limit Voltage.
e ) Boost Reconnect Charging voltage>Low Voltage Disconnect Voltage.
11. Disclaimer
This warranty does not apply under the following conditions:
Damage from improper use or use in an unsuitable environment.
PV or load current, voltage or power exceeding the rated value of controller.
The controller is working temperature exceed the limit working environment
temperature.
User disassembly or attempted repair the controller without permission.
The controller is damaged due to natural elements such as lighting.
The controller is damaged during transportation and shipment.
Website:www.epsolarpv.com/www.epever.com
40W/12V,80W/24V
4A/12V, 24V
Min. V
-0.5V
BAT
Sealed / Gel / Flooded / User
≤16mA(12V);≤20mA (24V)
-3mV/℃/2V
-35℃~+55℃
IP68(1.5m,72h)
107x68x20mm
100mm
Φ4
PV/BAT:14AWG(2.5mm
LOAD: 18AWG(1.0mm
0.25kg
Sealed
Gel
16.0V
16.0V
15.0V
15.0V
15.0V
15.0V
——
14.6V
14.4V
14.2V
13.8V
13.8V
13.2V
13.2V
12.6V
12.6V
12.2V
12.2V
12.0V
12.0V
11.1V
11.1V
10.6V
10.6V
——
120 min.
120 min.
120 min.
Any changes without prior notice! Version number:V1.0
4
50V
8V~32V
50W/12V,100W/24V
5A/12V,24V
Min. V
-1V
BAT
96%
≤50mA
IR
≤6m
≤15°
≤0.16V
108.5x88x25.6mm
100.5mm
Φ5
2
2
)
PV/BAT:12AWG(4.0mm
)
2
2
)
LOAD: 18AWG(1.0mm
)
0.39kg
Flooded
User
16.0V
9~17V
15.0V
9~17V
15.0V
9~17V
14.8V
9~17V
14.6V
9~17V
13.8V
9~17V
13.2V
9~17V
12.6V
9~17V
12.2V
9~17V
12.0V
9~17V
11.1V
9~17V
10.6V
9~17V
120 min. 0~180 min.