Epever LS1024B Hızlı Başlangıç Kılavuzu
Kontrolör Epever LS1024B için çevrimiçi göz atın veya pdf Hızlı Başlangıç Kılavuzu indirin. Epever LS1024B 2 sayfaları. Solar charge controller
Ayrıca Epever LS1024B için: Kullanıcı Kılavuzu (2 sayfalar)
HUIZHOU EPEVER TECHNOLOGY CO., LTD.
※Thank you for selecting the LS-B series solar charge controller. Please read
this manual carefully before using the product and pay attention to the safety
information.
Solar Charge Controller
1 Overview
LS-B series is a PWM common positive solar charge controller that adopts the advanced
digital technique. The multiple load control modes make it suitable for a solar home
system, traffic signal, solar street light, solar garden lamp, etc.
Features:
Adopt high-quality components of ST, and IR, ensure product lifespan
UL and VDE certification for terminals, make the product safer and more reliable
Full load running in the environment temperature range
3-stage intelligent PWM charging:Bulk, Boost/Equalize, Float
Optional four battery types: Sealed, Gel, Flooded and User
Battery temperature compensation function
Real-energy statistics function
Standard Modbus protocol based on RS485 bus, longer communication distance
Multiple load control modes
Extensive electronic protection
2 Identification of parts
❶
Remote temperature(RTS)port
❷
PV terminals
Battery terminals
❸
Load terminals
❹
❺
RS485 communication port
★ If the temperature sensor is short-circuited or damaged, the controller will charge
or discharge at the default temperature setting of 25 ºC (no temperature
compensation).
3 Wiring
Figure 2 Connection diagram
Installation Procedure:
Connect the system in the order of ❶battery
shown in figure 2 and disconnect the system in reverse order❸❷❶.
NOTE: While wiring the controller, please do not switch off the circuit breaker
or fuse and make sure that the leads of "+" and "-" poles are connected
correctly.
Figure 1 Characteristic
★
❻
Mounting hole
❼
Load ON/OFF button
❽
Load status indicator
❾
Battery status indicator
❿
Charge status indicator
❷ load
❸PV array
1
Tel:+86-10-82894896/82894112/+86-752-3889706
NOTE: A fuse which current is 1.25 to 2 times the rated current of the
controller must be installed on the battery side with a distance from the
battery not greater than 150 mm.
NOTE: The LS-B series is a positive ground controller. Any positive
connection of solar, load, or battery shall be earth grounded as required.
NOTE: If an inverter is to be connected to the system, connect the inverter
directly to the battery, not to the load side of the controller.
4 Indicator and button
(1) Indicator
Indicator
Color
Green
Green
Green
Green
Green
Green
Green
Orange
Red
Red
Red
Red
Red
Red
Charge, Load and Battery(orange)indicator flashing
Charge, Load and Battery(red)indicator flashing
(2) Button
① The load is turned ON/OFF via the button when the operating mode is Manual Control.
② Clear the faults for the overload and load short circuit.
5 Setting
❶ USB to RS485 converter cable: CC- RS485-RS485-150U
Download PC software: www.epever.com(PC Software for the Solar Charge Controller)
❷ USB to RS485 converter cable: CC- RS485-RS485-150U
OTG cable: OTG-12CM
Download phone APP (support Andriod system only)
www.epever.com(Andriod APP for the Solar Charge Controller)
❸ RS485 to RS485 converter cable: CC-RS485-RS485-200U-MT)
(1) Battery type
Battery voltage control parameters (Below values are measured in the 12V/25 ºC system;
please double the values in the 24V system.)
Battery type
Over Voltage Disconnect Voltage
Charging Limit Voltage
Over Voltage Reconnect Voltage
Equalize Charging Voltage
Boost Charging Voltage
Float Charging Voltage
Boost Reconnect Charging Voltage
Low Voltage Reconnect Voltage
Under Voltage Warning Reconnect
Voltage
Under Voltage Warning Voltage
Low Voltage Disconnect Voltage
Discharging Limit Voltage
Equalize Duration
Boost Duration
NOTE:
as
1) When the battery type is sealed, gel, flooded, the adjusting range of equalizing duration
is 0 to180 minutes, and boost duration is 10 to180 minutes.
2) The following rules must be observed when modifying the value of the parameter in the
user battery type (factory default value is the same as the sealed type):
Website:www.epever.com
Status
Information
PV connection normal ,but
On solid
low voltage(low irradiance)
from PV, no charging
No PV voltage(night time) or
OFF
PV connection problem
Slowly flashing(1Hz)
In charging
Fast flashing(4Hz)
PV over voltage
On solid
Battery normal
Slowly flashing(1Hz)
Battery full
Fast flashing(4Hz)
Battery over voltage
On solid
Battery under voltage
On solid
Battery over discharged
Slowly flashing(1Hz)
Battery over temperature
On solid
Load ON
OFF
Load OFF
Slowly flashing(1Hz)
Overload
Fast flashing(4Hz)
Load short circuit
Controller over temperature
System voltage error
Sealed
Gel
Flooded
16.0V
16.0V
16.0V
15.0V
15.0V
15.0V
15.0V
15.0V
15.0V
——
14.6V
14.8V
14.4V
14.2V
14.6V
13.8V
13.8V
13.8V
13.2V
13.2V
13.2V
12.6V
12.6V
12.6V
12.2V
12.2V
12.2V
12.0V
12.0V
12.0V
11.1V
11.1V
11.1V
10.6V
10.6V
10.6V
——
120 min
120 min
120 min 120 min
120 min
2
User
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
0~180 min
10~180
min