Epever Tracer2610BP Manuel - Sayfa 2

Kontrolör Epever Tracer2610BP için çevrimiçi göz atın veya pdf Manuel indirin. Epever Tracer2610BP 2 sayfaları. Solar charge controller
Ayrıca Epever Tracer2610BP için: Manuel (2 sayfalar), Hızlı Başlangıç Kılavuzu (2 sayfalar)

Epever Tracer2610BP Manuel
Accessory 1: Fixed Plate (Four)
Overall dimension:20×18×6mm/Mounting hole size:Φ3.5mm
Accessory 2: Wireless collector (eBox-WL433M-01)
Accessory 3: Super Parameter Programmer—SPP-02 and Remote Meter-MT50
Use USB to RS485 converter cable: CC- RS485-RS485-150U-22AWG
Accessory 4: PC monitoring setting software "Solar Station Monitor"
 Use USB to RS485 converter cable: CC-USB-RS485-150U-22AWG
Accessory 5: Mobile APP
 Use USB to RS485 converter cable: CC-USB-RS485-150U-22AWG
 Use OTG cable: OTG-12CM
 APP software can be downloaded from the website of http://www.epsolarpv.com.
Note: Accessory 3-5 can set parameters of the controller. Please refer to the user
manual of accessory.
8. Protection
 PV Over Current
The controller will limit battery charging current to the Maximum Battery Current
rating. Therefore an over-sized solar array will not operate at peak power.
 PV Short Circuit
When PV short circuit is powered on or PV input is short circuit on low-power, the
controller will stop charging. Clear it to resume normal operation.
WARNING: The controller may be damaged, when PV input is short
circuit on high-power.
 PV Reverse Polarity
Fully protection against PV reverse polarity, correct the wire connection to resume
normal operation.
WARNING: Controller will be damaged when the PV array straight
polarity and the actual operation power of the PV array is 1.5 times
greater than the rated charge power!
 Battery Reverse Polarity
Fully protection against battery reverse polarity, correct the wire connection to
resume normal operation.
 Battery Over Voltage
When the battery voltage reaches to the set point of Over Voltage Disconnect Voltage,
the controller will stop charging the battery to protect the battery from being over
charged to break down.
 Battery Over Discharge
When the battery voltage reaches to the set point of Low Voltage Disconnect Voltage,
the controller will stop discharging the battery to protect the battery from being over
discharged to break down.
 Battery Overheating
The controller detects the environment temperature through the external temperature
sensor. If the environment temperature exceeds 65 º C, the controller will automatically
start the overheating protection to stop working, and recover below 55 º C.
 Lithium battery Low Temperature
The temperature sensor is less than the low temperature value, Lithium battery stop
charging/discharging. It is higher than the low temperature value, Lithium battery start
charging/discharging.
 Load Overload
If the load current exceeds the maximum load current rating 1.05 times, the controller
will disconnect the load. Overloading must be cleared up through reducing the load
and restarting controller.
 Load Short Circuit
Load will be switched off when load short circuit (≥4 times rated current) happens.
Controller will automatically attempt to reconnect load for 5 times. If short circuit
10. Technical Specifications
Item
Model
Nominal system voltage
Battery input voltage range
Rated charge current
Rated charge power
Max. PV open circuit voltage
MPP Voltage range
Battery Type
Equalize Charging Voltage
Boost Charging Voltage
Float Charging Voltage
Low Voltage
Reconnect Voltage
Low Voltage
Disconnect Voltage
Self-consumption
Temperature compensation
coefficient
Communication
Working environment
temperature
Enclosure
Overall dimension
Mounting hole size
Mounting dimension
Power cable
Net weight
※The parameters are 12V system at 25 º C, please double the values in 24V system.
#Lithium battery do not automatic identification system voltage and no temperature compensation coefficient.
BEIJING EPSOLAR TECHNOLOGY CO., LTD.
Tracer2606BP
Tracer3906BP
10A
15A
130W/12V
195W/12V
260W/24V
390W/24V
60V( at minimum operating environment temperature )
46V( at 25℃ environment temperature )
( Battery voltage+2V)~36V
Sealed :14.4V/Gel:14.2V/Flooded:14.6V※; LiFePO4:14.6V/ Li-NiCoMn:12.51V / User:9-34V
Sealed/Gel/Flooded:13.8V※ ; LiFePO4:14.4V / Li-NiCoMn:12.39V / User:9-34V
Sealed/Gel/Flooded:12.6V※ ; LiFePO4:12.0V / Li-NiCoMn:10.8V / User:9-34V
Sealed/Gel/Flooded:11.1V※ ; LiFePO4:10.6V / Li-NiCoMn:9.3V / User:9-34V
124×89×30mm
150×93.5×32.7mm
88×76mm
120×83mm
PV/BAT/LOAD:14AWG(2.5mm
0.54kg
0.74kg
3
Tel:+86-10-82894112 / 82894962 Website:www.epsolarpv.com/www.epever.com
protection still exist after controller's 5 times attempts, user have to clear short
circuit ,then restart the controller or wait for one night-day cycle (night time>3 hours).
 Temperature sensor break down
If the temperature sensor short-circuited or damaged, the controller will be charging
or discharging at the default temperature 25 º C to prevent the battery damaged from
overcharging or over discharged.
 High Voltage Transients
The controller is protected against small high voltage transients. In lightning prone
areas, additional external suppression is recommended.
9. Troubleshooting
Faults
LED Charging
indicator turn off
during daytime
when sunshine falls
on PV modules
properly
No LED indicator
Battery LED
indicator green fast
Flashing
Battery LED
indicator red
Battery LED
indicator red
flashing
Load is not output
①When it is overload or short circuit, the load have 5 times auto-recovery output
function, which each times delay respectively 5s, 10s, 15s, 20s, 25s.
11. Disclaimer
This warranty does not apply under the following conditions:
 Damage from improper use or use in an unsuitable environment.
 PV or load current, voltage or power exceeding the rated value of controller.
 The controller is working temperature exceed the limit working environment
temperature.
 User disassembly or attempted repair the controller without permission.
 The controller is damaged due to natural elements such as lighting.
 The controller is damaged during transportation and shipment.
Tracer5206BP
Tracer2610BP
12/24VDC Auto
9~32VDC
20A
260W/12V
520W/24V
Sealed(Default) / Gel / Flooded ; LiFePO4/ Li-NiCoMn/User
Sealed :14.6V/Gel:No / Flooded:14.8V※; No
≤13mA/12V;≤11.5mA/24V
-3mV/℃/2V
RS485
-40℃~+60℃
IP67
153×105×52.1mm
124×89×30mm
Φ3.5mm
120×94mm
2
)
1.20kg
Possible reasons
PV
Confirm that PV and battery wire
array disconnection
connections are correct and tight
Measure battery voltage with the
Battery voltage maybe
multi-meter. Min.9V can start up the
less than 9V
controller
Check if battery voltage is higher
Battery over voltage
than OVD, and disconnect the PV
When the battery voltage is restored
Battery
to or above LVR point (low voltage
over discharged
reconnect voltage), the load will
recover
The controller will automatically turn
the system off. But while the
Battery Overheating
temperature decline to be below 50
º C, the controller will resume.
①Please reduce the number of
electric equipments.
②Restart the controller.
Load Overload
③wait for one night-day cycle (night
time>3 hours).
①Check carefully loads connection,
clear the fault.
②Restart the controller.
Load Short Circuit
③wait for one night-day cycle (night
time>3 hours).
Any changes without prior notice! Version number:V1.0
Tracer3910BP
10A
15A
130W/12V
195W/12V
260W/24V
390W/24V
100V( at minimum operating environment temperature )
92V( at 25℃ environment temperature )
( Battery voltage+2V)~72V
150×93.5×32.7mm
88×76mm
120×83mm
PV/BAT/LOAD:12AWG(4mm
0.54kg
0.74kg
4
Troubleshooting
Tracer5210BP
20A
260W/12V
520W/24V
153×105×52.1mm
120×94mm
2
)
1.20kg