4) Real-time Control
Control the load ON/OFF time through setting real-time clock.
5) Intelligent Power Mode
When the battery voltage is lower than "Under Warning Recover Voltage (UWRV
adjustable)", the intelligent power mode is enabled; at this time, the LED current
percentage will be automatically reduced in linear with the voltage drop of battery. When
the battery voltage is lower than "Under Warning Recover Voltage (WRW adjustable)", a
minimum LED current percentage (default 2%, adjustable) will be output. In addition,
when the battery voltage is higher than UWRV, the controller will exit the intelligent
power mode.
NOTE: In the mode of Light ON/OFF and Light ON/Timer, the Load is
turned on after 1Min. delay.
7. Setting Operation
There are three methods that it can realize controller
load modes and parameters through IR function:
1) IR Remote Control—RC10
2) Super Parameter Programmer—FC-01
This method can realize one-key setting operation
which is suitable for bulk quantity products setting or
applied in the projects.
3) Mobile APP+eBox-WIFI&IR-01/02
Real-time monitoring and setting the parameters
Note: Please refer to the user manual of handheld
device
8. Protection
Protection
Conditions
PV Reverse
When the battery is correct
Polarity
connecting, the PV can be reversed.
Battery Reverse
When the PV is not connecting, the
Polarity
battery can be reversed.
Battery Over
The battery voltage reaches to the OVD Stop charging
Voltage
Battery Over
The battery voltage reaches to the LVD
Discharge
Temperature sensor is higher than 65℃ Output is OFF
Battery
Overheating
Temperature sensor is less than 55℃
Temperature sensor is less than the
Lithium battery
low temperature value
Low Temperature
Temperature sensor is higher than the
(Default 35℃)
low temperature value
Limit current temperature
Lithium battery
limit current in
T1>T2>T3>T4>T5>T6
low temperature
Limit current I1>I2>I3>I4>I5>I6
10. Technical Specifications
Item
Tracer1305LPLI
Nominal system voltage
8.5~16VDC
Battery input voltage range
Rated charge current★
Rated charge power
50V(Min. Temp.)
Max. PV open circuit voltage
MPP Voltage range
Max. output current
Max. output power
( Max. battery
Output voltage range
voltage+2V)~46V
Load open circuit voltage
Load over voltage protection
Maximum output efficiency
Output current control accuracy
Battery Type
Equalization Voltage
Boost Voltage
Float Voltage
Low Voltage
Reconnect Voltage
Low Voltage Disconnect
Voltage
Boost Charging Voltage
Low Voltage Reconnect
Voltage
Low Voltage
Disconnect Voltage
Self-consumption
Communication
Working environment Tem.
Enclosure
Overall dimension
Mounting hole size
Mounting dimension
Power cable
Net weight
★The controller has the limit charge current function, the current can be set via the APP software and RC10.
HUIZHOU EPEVER TECHNOLOGY CO., LTD.
Status
The controller is not
damage
stop discharging
Output is ON
Lithium battery stop
charging
Lithium battery charging
When the temperature is
lower
than
charging current is I1;
when the temperature is
lower
than
charging current is I2;
and so on. However,
when
the
temperature
rises gradually from T4 to
T1, it is performed at I4.
Tracer2606LPLI
12VDC
10A/12V
10A
130W/12V
130W/12V;260W/24V
60V(at minimum operating environment temperature)
45V(25℃)
46V(at 25℃ environment temperature)
( Battery voltage+2V)~36V
3.3A
3.3A
100W
100W
( Max. battery voltage+2V)~58V
46V
50V
Lead-acid battery: Sealed(default)/Gel/Flooded/User; Lithium battery:LiFePO4/Li-NiCoMn/User
Sealed:14.4V;Gel:14.2V;Flooded:14.6V;User:9-17V(24Vsystem×2)
LiFePO4(4s):14.5V/Li-NiCoMn(3s):12.5V/User:9-17V(24Vsystem×2)
LiFePO4(4s):12.8V/Li-NiCoMn(3s):10.5V/User:9-17V(24Vsystem×2)
LiFePO4(4s):11.1V/Li-NiCoMn(3s):9.3V/User:9-17V(24Vsystem×2)
124×89×30mm
150×93.5×32.7mm
88×76mm
2
PV/BAT:14AWG(2.5mm
)
2
LOAD:18AWG(1.0mm
)
0.52kg
0.52kg
3
Tel:+86-10-82894896/82894112/+86-752-3889706
Load Short
Circuit
9. Troubleshooting
Faults
LED Charging
indicator turn off
during daytime
when sunshine falls
on PV modules
properly
No LED indicator
Battery LED
indicator green fast
Flashing
Battery LED
indicator red
Battery LED
indicator red
flashing
Powering on
normally, the load is
off
The dimming
function is invalid
T1,
the
Parameter settings
fail
①When the battery is over discharged, the battery indicator will be red and the load will be
T2,
the
off all the time before the voltage is more than the Low Voltage Reconnect Voltage (LVRV).
In order to judge the system is normal or not, firstly measuring the battery voltage whether
is more than LVRV, if not, restarting the controller to detect the load whether it is normal.
NOTE: The LVRV can be set, but it must pay more attention that it maybe damages
the battery if the LVRV is too low.
Tracer3906LPLI
Tracer5206LPLI
12/24VDC
8.5~32VDC
15A
20A
200W/12V;400W/24V
260W/12V;520W/24V
4.5A
6.6A
130W
200W
58V
63V
96%
≤2%
Sealed:14.6V; Flooded:14.8V;User:9-17V (24Vsystem×2)
Sealed/Gel/Flooded:13.8V;User:9-17V(24Vsystem×2)
Sealed/Gel/Flooded:12.6V;User:9-17V(24Vsystem×2)
Sealed/Gel/Flooded:11.1V;User:9-17V(24Vsystem×2)
≤15mA/12V;≤22mA/24V
IR communication
-40℃~+60℃
IP68(1.5m,72h)
153×105×52.1mm
Φ3.5mm
120×83mm
120×94mm
PV/BAT:12AWG(4mm
LOAD:16AWG(1.5mm
0.71kg
1.18kg
Load current ≥2.5 times rated current
One short circuit, the output is OFF 5s;
Two short circuit, the output is OFF 10s;
Three short circuit, the output is OFF 15s;
Four short circuit, the output is OFF 20s;
Five short circuit, the output is OFF 25s;
Six short circuit, the output is OFF
Possible reasons
PV
Confirm that PV and battery wire
array disconnection
connections are correct and tight
Measure battery voltage with the
Battery voltage maybe
multi-meter. Min.8.5V can start up
less than 8.5V
the controller
Check if battery voltage is higher
Battery over voltage
than OVD, and disconnect the PV
When the battery voltage is restored
Battery
to or above LVR point (low voltage
①
reconnect voltage), the load will
over discharged
recover
The controller will automatically turn
the system off. But while the
Battery Overheating
temperature decline to be below 50
º C, the controller will resume.
①The connecting
① Check the connecting cable.
wires are error or
② Check the load's mode and
virtually connected
parameters.
②Load mode is not
③The voltage of LED light is not
appropriate.
within the output voltage range of
③This controller does
controller.
not match with the LED
④Check the connecting cables and
light.
LED light.
④Output short circuit.
The controller does not
①Replace the LED light
match with the LED
②Reduce system rated voltage
light source. This
grade and replace the product
product is a step-up
model
voltage control, If input
For example 24V system change to
voltage is lower than
12V system, and replace the
the rated voltage, it is
corresponding controller
not working.
Infrared
Refer to handheld the user device
communication error
manual
Tracer2610LPLI
Tracer3910LPLI
10A
15A
130W/12V;260W/24V
200W/12V;400W/24V
100V(at minimum operating environment temperature)
92V(at 25℃ environment temperature)
( Battery voltage+2V)~72V
3.3A
4.5A
100W
130W
( Max. battery voltage+2V)~80V
80V
100V
124×89×30mm
150×93.5×32.7mm
88×76mm
120×83mm
2
2
)
PV/BAT:14AWG(2.5mm
)
2
2
)
LOAD:18AWG(1.0mm
)
0.52kg
0.71kg
Any changes without prior notice! Version number:V1.4
4
Website:www.epever.com
Output is OFF
Clear the fault: Restart
the controller or wait for
one night-day cycle (night
time>3 hours).
Troubleshooting
Tracer5210LPLI
20A
260W/12V;520W/24V
6.6A
200W
153×105×52.1mm
120×94mm
2
PV/BAT:12AWG(4mm
)
2
LOAD:16AWG(1.5mm
)
1.18kg