Epever SHI3000-22 Kullanıcı Kılavuzu - Sayfa 14
İnvertör Epever SHI3000-22 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Epever SHI3000-22 20 sayfaları. Shi series pure sine wave inverter
5. Troubleshooting
WARNING:
High voltage is inside the inverter, do not open or
disassemble it! Attempting to service the unit yourself
may cause the risk of electrical shock or fire!
Problem
Input LED blink,
fault red LED
slow blink
Load LED blink,
fault red LED fast
blink
Fault orange
LED fast blink
Fault red LED
Possible
Cause
Input voltage is
too high or too
low
Overload or load
short
Over
temperature
inside the
inverter
Inverter
abnormal
12
Solution
Measure the input
voltage. The inverter
recovers when the input
becomes normal.
Check out if the AC load
is within the rated power
or whether there is load
short.
Improve the quality of
ventilation and do not
block the vent. Restart
the inverter when it is
cool down.
Remove all the
connected plugs then
restart. If inverter works
well, please check the