ALPHA WORKS GUT109 Operatör El Kitabı - Sayfa 5
Boya Püskürtücü ALPHA WORKS GUT109 için çevrimiçi göz atın veya pdf Operatör El Kitabı indirin. ALPHA WORKS GUT109 17 sayfaları. 12v lithium ion battery powered electrostatic 34oz hand-held sprayer
IMPORTANT SAFETY INSTRUCTION FOR CHARGING
1. Always fully charge before use.
2. Always use Alphaworks charger to charge Alphaworks sprayer battery. Use of other types
of chargers may cause battery damage and in some instances injury to operator.
3. Never operate charger with damaged battery, cord, or plug. Replace them immediately.
4. Never use Alphaworks charger to charge nonauthorized Alphaworks batteries.
5. The charging Indicator Located on Charger. When battery is charging, the LED turns to solid
red and turns to green when battery is fully charged.
6. Battery capacity check-LED on product.
75%~100% battery charge: 4 Solid Green LED
50%~75% battery charge: 3 Solid Green LED
25%~50% battery charge: 2 Solid Green LED
0~25% battery remaining: Left LED turns to Solid Red
Battery Depleted: Left LED flashing red and Sprayer will stop working
7. ESD Function:
a) ESD function is controlled by ON/OFF button.
b) Blue LED is flashing: ESD is working.
c) Blue LED not flashing: ESD is now shut off.
ELECTRICAL HAZARD
1. Always use properly grounded single-phase receptacle protected by a ground fault circuit
interrupter (GFCI).
2. Never remove ground pin from plug.
3. Never route electrical cables across sharp edges.
4. Never route electrical cables through or near moving parts.
5. Never route electrical cables near parts that become hot.
6. Never remove electrical cover from battery charger.
7. Never leave the puling tool power cord plugged in when installing, rigging, servicing or when
the puling too is not being used.
8. Never disconnect ground bond.
9. Never operate AC pulling tool in a damp or wet environment.
10. Always power the sprayer with only the recommended electrical system voltage, See the
sprayer specification sheet for details.
11. Never operate charger if it has received a sharp blow, been dropped or otherwise damaged
in any way.
12. Never charge in damp or wet environment.
13. Always charge at temperatures between 32°F-120°F (0°C-49°C).
14. Always store at temperatures between 32°F-86°F (0°C-30°C).
15. Always disconnect charger when it's fully charged.
16. Never probe with conductive object.
17. Always fully charge before use.
18. Never completely discharge.
19. Always charge every six months if not in use.
TROUBLESHOOTING
Problem
Machine run, no spray.
Intermittent spray,
small spray.
Machine abnormal
sounds.
No ESD function.
Machine does not work .
Possible Cause
Chemical tube blocked.
Spay nozzle block.
Pump damaged.
The ESD switch is not on.
Nozzle or tube blocked .
Corrective Action
Clean up or replace.
Clean the spray nozzle
Replace the pump.
Turn on the ESD switch.
Remove the nozzle and
clean the tube.
E3