Axminster UE-127DV1 Kullanıcı Kılavuzu - Sayfa 11

Testere Axminster UE-127DV1 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Axminster UE-127DV1 16 sayfaları. Portable band saw

Axminster UE-127DV1 Kullanıcı Kılavuzu
2.
Remove the blade guard by loosening two
screws (U) in Fig. 9 on the saw frame.
3.
Remove blade cover by loosening four
screws (V) in Fig.10 on the saw frame.
V
Fig. 10
4.
Turn the blade tension wheel (W) in Fig.11,
Counter-clockwise let the blade slip off.
Fig. 11
U
Fig. 9
W
5.
Remove blade from both wheels and blade
guides bearings (X) in Fig.12.
6.
Place a new blade on the wheels but not
too tight, twist blade slightly and let it slip
into between each of guide bearings. Make
sure the teeth of blade face down toward
the bed.
7.
Turn the tension wheel clockwise to make
the blade tension be tensioned properly.
8.
Replace blade cover (V) in Fig.10 and
guards Fig.9.
9.
Start the machine to see that the blade runs
properly.
Caution: Be sure that the machine is
disconnected from the power source before
attempting to service or take any
component away!

Magnetic Switch

The band saw is equipped with magnetic switch
in Fig.13, which is designed for operating safety.
After power failure, the machine has to be
restarted by pushing the green "ON" button.
There is a red button, which depresses it to stop
all machine functions.
ON
OFF
- 9 -
X
Fig. 12
Fig. 13