Now fit the inlet adaptor with the single self tapping screw as shown
(Figures 14, 15 & 16).
Figure 14
Figure 16
Security Breaker
105781
Power Supply Circuit
105783
Power Supply Circuit
105784
Power Supply Circuit
Figure 15
Remote control
Timer
1.5HP 230V 50Hz 1Phase
16 Amps (Type C Breaker)
2HP 230V 50Hz 1Phase
16 Amps (Type C Breaker)
3HP 230V 50Hz 1Phase
16 Amps (Type C Breaker)
ASSEMBLY INSTRUCTIONS
The manometer gauge is your
machine performance indicator, it is
a visual indicator that the machine,
and your system is functioning. If
the needle is in this region then
enough air flow is reaching the
machine to enable it to function
correctly.
You must operate the filter cleaning
lever (AP154/AP176 CEH) very
regularly to maintain the filter
performance. The AP357CEH is
fitted with electric filter cleaning
which operates when the machine
is switched off.
The filter has a very long life, and barring damage, even when partially
clogged can be cleaned from the inside with an "M" Class vacuum
cleaner. Never use a high pressure blow gun from the outside to disturb
dust that may be attached to the inside surface.
The golden rule with filter cleaning is little and often.
7
Figure 17
WIRING DIAGRAM
Wiring of remote control