Axor One 45713 3 Series Montaj Talimatları Kılavuzu - Sayfa 2
Sıhhi Tesisat Ürünleri Axor One 45713 3 Series için çevrimiçi göz atın veya pdf Montaj Talimatları Kılavuzu indirin. Axor One 45713 3 Series 16 sayfaları.
EN
0 2
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
Children as well as adults with physical, mental and/or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
F A U L T
⁄ Insufficient water
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Spout temperature does not correspond with temperature
set
⁄ Temperature regulation not possible
⁄ Instantaneous heater didn't work with thermostat
A S S E M B L Y (see page 07)
S Y M B O L D E S C R I P T I O N
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C ⁄ 4 min
C A U S E
⁄ Supply pressure inadequate
⁄ Regulator filter dirty
⁄ Shower filter seal dirty
⁄ Backflow preventers dirty or leaking
⁄ Thermostat has not been adjusted
⁄ Hot water temperature too low
⁄ thermo cartridge calcified
⁄ Filters are dirty
⁄ check valve hasn't moved back
⁄ Flow limiter in handshower isn't removed
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 12)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
S A F E T Y F U N C T I O N (see page 12)
D I M E N S I O N S (see page 43)
F L O W D I A G R A M (see page 10)
M A I N T E N A N C E (see page 13)
⁄ The check valves must be checked regularly according to EN 806-5 in
accordance with national or regional regulations (at least once a year).
⁄ The mixer is equipped with check valves. To guarantee the smooth running
of the thermostat, it is necessary from time to time to turn the thermostat
from total hot to total cold.
S P A R E P A R T S (see page 14)
XX = Colors
00 = Chrome Plated
67 = Matt Black
+
S P E C I A L A C C E S S O R I E S (see page 15)
order as an extra
extension 25 mm #45790000
C L E A N I N G (see page 11)
O P E R A T I O N (see page 08)
R E M E D Y
⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Clean filter in front of the mixer and on the MTC-thermo car-
tridge
⁄ Clean filter seal between shower and hose
⁄ Clean backflow preventers, exchange if necessary
⁄ Adjust thermostat
⁄ Increase hot water temperature to 42 ºC to 60 ºC
⁄ Exchange thermo cartridge
⁄ Clean the filter / exchange filter
⁄ Exchange check valves
⁄ Remove flow limiter