Choose a location where there will be a sufficient incline for drainage pipes and where the
ground is considered to be well drained and stable. The pit should be at least 50 cm around
the tank's external dimensions.
The tank must not be located where there is a risk of being driven over, e.g. by cars; where
there is a risk at any time of the year that the groundwater level reaches the inlet pipe or
where the ground is marshy and unstable. Consideration should also be given to the frost
depth of the location.
Remember to:
Investigate the maximum permitted distance and suction height for waste removal vehicles
for the areas prior to installation.
Material
The tank should be placed on a 150 mm thick
and well flattened bed of fine gravel or sand without
any sharp stones that can harm the tank.
Ideally this bed should be compressed by using a vibrator.
If there is any risk the ground water level can reach
up to the bottom of the tank it should then
be secured. At empty tank and maximum permitted ground
water level the lifting impact is 30 000 N which is comparable
with 3 000 kg. To keep the tank in place the anchoring
strength must have corresponding power. The tank can be
secured with soft bands or specific anchoring canvas.
Note:
The lifting force for an empty tank and
maximum permitted groundwater level is 30,000 N!
Equivalent to a lifting force of 3,000 kg.
Tank pit
Securing of the tank