Factory reset (0x05)

This command resets the unit to factory defaults.
Example
Command/response sequence for resetting the unit to factory defaults:
Command:
0x21 0x01 0x05 0x02 0xAA 0xAA 0x0D
Response:
0x21 0x01 0x05 0x00 0x00 0x0D

Simulate RC5 IR command (0x08)

Simulate an RC5 command via the RS232 port. An additional status message
will be sent in most cases as a result of the IR command.
Example
Command/response sequence to RC5 16-17 (volume down):
Command:
0x21 0x01 0x08 0x02 0x10 0x11 0x0D
Response:
0x21 0x01 0x08 0x00 0x02 0x10 0x11 0x0D
COMMAND:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x05
Dl
0x02
Data1
0xAA (Confirmation data pattern to avoid accidental restore)
Data2
0xAA (Confirmation data pattern to avoid accidental restore)
Et
0x0D
RESPONSE:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x05
Ac
Answer code
Dl
0x00
Et
0x0D
COMMAND:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x08
Dl
0x02
Data1
RC5 System code
Data2
RC5 Command code
Et
0x0D
RESPONSE:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x08
Ac
Answer code
Dl
0x02
Data1
RC5 System code
Data2
RC5 Command code
Et
0x0D
7