ABB Jocab Safety Vital 3 Manuel - Sayfa 4

Kontrolör ABB Jocab Safety Vital 3 için çevrimiçi göz atın veya pdf Manuel indirin. ABB Jocab Safety Vital 3 14 sayfaları. Safety controller
Ayrıca ABB Jocab Safety Vital 3 için: Kullanım Talimatı (11 sayfalar)

ABB Jocab Safety Vital 3 Manuel
Technical data – Vital 1
Manufacturer
Article number/Ordering data:
Vital 1
Level of safety
EN ISO 13849-1
EN 62061
IEC/EN 61508-1...7
EN 954-1
PFH
D
Colour
Weight
Power supply
Vital, A1-A2
From Vital to sensors/units, B1-B2
Fuse
An external fuse should be fitted
in the supply to A1
Max line resistance
at nominal voltage to X1
Power consumption
DC supply, nominal voltage
(without load)
DC supply, nominal voltage
(with max load)
Dynamic safety circuit
T 1
R 1
Reset input X1
Supply for reset input
Reset current
Minimum contact closure time
for reset
Connection of S1
Even numbers of sensors (Eden + Spot T/R + Tina) require a
connection between B1 and S1. S1 is not connected for odd
numbers of sensors. Odd number, no connection between B1 and
S1.
Number of sensors
Max. number of Eden/Tina to
Vital 1
Total max. cable length to Eden/
Tina
Max. number of Spot T/R to Vital
Total max. cable length to Spot
T/R
Maximum number of units varies depending on the installation and
cable size. For more information, see the examples in this chapter.
Response time
At Power on
When activating (input-output)
When deactivating (input-output)
At Power loss
Relay outputs
NO
Max switching capacity, resistive
load
Minimum load
Contact material
Mechanical life
External fuse (EN 60947-5-1)
ABB
ABB AB/Jokab Safety, Sweden
2TLA020052R0000
PL e, category 4
SIL 3
SIL 3
Category 4
-8
2.74×10
Grey
220 g
24 VDC ±15%
24 VDC
3 AT
150 Ohm
3 W
48 W
Output signal
Input signal
+24VDC
30 mA max. (inrush current
300 mA during contact closure)
80 ms
30
1000 m
6 pairs
600 m
< 65 ms
< 40 ms
< 48 ms
< 55 ms
2
6A/250 VAC/1500 VA/150W
10 mA/10V
AgCdO
>10
7
operations
6.3A or 4A slow
Relay information output
(changeover contact)
Y14
–(0V)
+(24V)
Max. load on Y14
LED indication
On
T
R
1
Mounting
DIN rail
Operating temperature range
Connection blocks (detachable)
Max screw torque
Max connection area:
Solid conductors
Conductor with socket contact
Air and creep distance
Protection class
Enclosure
Connection blocks
Conformity
Connector blocks are detachable
(without cables having to be disconnected)
Indicates Vital is not reset
Indicates Vital is reset
200 mA (Internal automatic fuse)
Fixed light: supply voltage OK,
Flashing light: under-voltage or
overload.
T: Signal out OK. R: Signal in OK.
2
Indicates that the output relays
have been activated
35 mm DIN rail
-10°C to + 55°C
1 Nm
2
2
1x4 mm
/2x1,5 mm
/12AWG
2
2
1x2,5 mm
/2x1 mm
4kV/2 DIN VDE 0110
IP 40 IEC 60529
IP 20 IEC 60529
EN ISO 12100-1, -2, EN 954-1,
EN ISO 13849-1, EN 62061,
EN 60204-1, IEC 60664-1,
EN 61000-6-2, EN 61000-6-4
EN 60947-5-1, EN 1088,
EN 61496-1, IEC/EN 61508-1...7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
5:9