LOADING DEFAULT LISTS (Only in Parallel Mode CCL-P)
CCL-P board allows you to change all values. Beside this, you can load default lists at any time.
Default lists are adjusted as such that -1, 0, 1, 2..... or 0, 1, 2, 3 from floor 0 to top floor. You can load
all these values at one step.
When you set Floor 0 to a value such as -2 and if you save it by holding ENT, DEC (↓) and INC (↑)
buttons all, then the next floors automatically set to -1,0,1...
RUN MODE
Push and hold INC (↑) and DEC (↓) button to enter run mode settings. In this menu system allows you
to set
Floor Selector
Board ID (Only in CANBus CCL-S/CCT)
Floor Number
Sliding Displays
FLOOR SELECTOR
CCL-P board can be driven by 7 Segment, Gray Code, Binary Code or Counter systems inputs, CCL-S
and CCT can be driven by CANBus. Additional to floor selectors, simulation mode can be set to
simulate system work.
RM letters on display shows Run Mode. Submenus of this mode are
BN:
Binary Code
GR:
Gray Code
7S:
7 Segment
CN:
Counter
CB:
CANBus
SM:
Simulation
ID DEFINITION
(Only in CANBus CCL-S/CCT)
ID information (0 to 63) of CCL-S/CCT board must be set to identify address of it in CANBus
communication. ID letters on display shows this menu.
FLOOR COUNT DEFINITION
Floor count at simulation mode can be set in this menu. SF letters on display shows this menu.
SLIDE DISPLAY SETTINGS
Set this menu to 1 for floor information set as a slide type at changes. SL letters on display shows this
menu.