Digiflex SMART RF RF120 Yükleyici Referans Kılavuzu - Sayfa 6

Alıcı-Verici Digiflex SMART RF RF120 için çevrimiçi göz atın veya pdf Yükleyici Referans Kılavuzu indirin. Digiflex SMART RF RF120 8 sayfaları. Base station with relay outputs

Optional RF110FK Fascia Kit
An option fascia kit is available to allow customers to
personalise their keyfob or to match corporate colours
etc. Each kit is supplied with 7 different coloured facias
which have been pre-installed onto top covers.
To change a fascia simply remove the screw from the
back of the keyfob, lift off the existing top cover and
fascia then replace with the new colour. Note keyfob
rubber keymats are not supplied with the kits.
Figure 10: RF110FK Colour Fascia Kit
RF121 Outputs
Each RF121 Base Station includes 4 relays that can be
used to increase the number of programmable outputs
available on the system.
Outputs can be used to operate LED indicators, control
garage doors, lighting, sprinklers, pumps, air condition-
ing or door strikes etc.
RF121 Output Allocations
Address Setting
Module
Number
SW1 SW2 SW3 SW4
1 =
OFF OFF OFF OFF
2 =
ON OFF OFF OFF
3 =
OFF ON OFF OFF
4 =
ON ON OFF OFF
Up to 4 x RF Base Stations can be installed. You can
use a mixture of RF120 and RF121 units.
Table 4: RF121 Address Configuration and Output Allocations
Please note that when using the RF121 you cannot
i
assign the same address to a CM710 Relay Module
Note
or CM705 Universal Expander Module. You should
assign these to higher module numbers.
Page
6
P/N: RF120-RF121IRG Rev 1.30
Output Number
9 to 12
13 to 16
17 to 20
21 to 24
Programming
Output programming options are fully detailed in the
control panel installation manual and quick reference
guides. The following sequence outlines the correct
output programming procedure.
1) Program the Output Name
Output names are used to simplify programming, user
interaction and reporting.
2) Select the Output Event Type
Over 60 different event types are available to suit a vari-
ety of applications.
3) Program the Output Event Assignment
Assigns the output to a specific user, zone, area or door
assignment etc.
4) Select the required Output Polarity
Configures how the output behaves (eg. Operates for
fixed period of time, pulses etc).
5) Program the Output Time Parameter
Sets how long the output will turn on or off for.
6) Select any required Output Options
Defines various options including to display or not dis-
play a trouble event when the output device is missing
etc.
E&OE
Copyright © 2021