3. Engage the Manual Over-ride Lever. The display will flash 'S C' and the motor will
start running slowly.
4. Check that the gate is closing, in which case skip to 6. If not, go to step 5.
5. Pull the Manual Over-ride Lever. Referring to Fig.1, swap the Motor wires on the
second plug. Re-engage the Manual Over-ride Lever and the motor will close.
6. On reaching the closed position, the operator will detect the rail-stop and halt.
The display will show "C" for closed.
If the gate has stopped short of the fully closed position, this is an indication of the
amount of power required by the gate, considering all the related factors.
The power setting and Obstacle Sensing are directly related, and should be increased
incrementally and re-tried until the gate reaches the closed position on the lowest
possible obstacle setting. If, on the highest setting of 3, the gate still fails to close fully,
then the gate is possibly too heavy (greater than 400 Kg), or there is too much rolling
resistance due to the condition of the track, the size of the wheels related to the weight
of the gate, or the state of the wheel bearings and guide rollers. Also check that the
rack is engaging smoothly with the gear, showing the correct clearance over the full
length of travel.
Programming Overview
Note: Programming mode may be entered only if 'C' (for closed), 'S-n' (Seek stopped)
or if a fault code 'F' is displayed.
Programming of features is achieved by pressing the Enter (ENT) and Select (SEL)
buttons together. The Program Display will show 'P'. Thereafter every press of the SEL
button will cause a different letter to appear, each representing different features.
When the required letter appears, press ENT to program that feature, and the letter will
start flashing. Use SEL to step through the setting options and ENT to confirm the
selection. After the display returns to 'P', press ENT to exit.
Limits (L)
1. As above, press ENT and SEL together and 'P' will appear on the display.
2. Press the SEL button. The Display will change to 'L'.
3. Press the ENT button and the 'L' will start flashing.
4. Press the ENT button again and the motor will open slowly to detect the rail-stop.
5. The operator will automatically close again at normal speed, leaving a small gap
before the stop, and the Display will show 'C'. The Limits have now been
programmed.
Obstacle Sensing (o)
1. Press SEL until 'o' is displayed. Levels 1, 2 and 3 of sensitivity may be selected, 1
being the most sensitive and 3 the least.
2. Press ENT and the 'o' and a digit will flash.
3. Press SEL until the desired option is displayed.
4. Press ENT to confirm the selection.
Note: Start with this setting on 1, and increase it if, during normal running, the gate stops
or reverses.
Next, record the Digitronic e-Key Remote control(s) as follows:
Record Remote (r)
1. Press SEL until 'r' is displayed.
2. Press ENT and the display will flash 'r n' (for "new" remote).
3. Press the desired button on the e-key Remote. The decimal point on the display will
flash.
4. Release the button and 'r C' will be flash. ('C' for 'confirm').
5. Press the same e-key Remote button to confirm the code.
6. Release the button and the display will flash 'r n', ready for the next remote, if any.
7. Repeat from step 3 for each required e-key Remote.
4