Ayra ERO 540 MKII Kullanıcı Kılavuzu - Sayfa 9

Işık Fikstürü Ayra ERO 540 MKII için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Ayra ERO 540 MKII 11 sayfaları. Rgb led movinghead

Moving parts are not functioning
well, values do not match and/or
rattling sounds are noticed
The fixture does not respond fast
enough to the set speed on my
DMX controller
The fixture does not respond to all
DMX-channels
Signal loss or distortion in DMX
values
Faulty stepping motor positioning
Moving parts can not keep up with
the set speed
Wrong DMX channel mode
Apply a DMX booster in your DMX
chain after 32 fixtures or less. After
a maximum of 32 fixtures the DMX
signal needs to be refreshed.
Possible value loss of stepping
motors. Activate the reset function,
or unplug the power supply and
plug it back in to activate the reset
program. This will reset all values
to the original 0-point.
Decrease the chase speed of your
DMX controller, as the stepping
motors of your fixture need some
time to move from one point to
another.
Check the DMX channel mode of
the fixture. If the wrong value is
set, change the channel mode to a
different setting and try again.