VENTING YOUR OVEN:
1 . The purpose of ventilating hoods is to direct and
capture smoke, grease-laden vapors, heat, odors, or
fumes .
2 . Low temperature equipment (maximum temperature
250°F/121°C) does not produce heat, odors, fumes,
grease-laden vapors or smoke and is not required to be
vented .
UNIT SPECIFICATIONS: All units use three (3) elements (2670 watts each) .
All units are rated 8000 watts . Water units have one (1) immersion element (1850 watts) .
MODEL NOS.
CONVECTION OVENS
CO-151-FWUA-12DX2081BC
Are rated at 4700 watts (Three [3] heaters at 1470 watts each)
HALF-SIZE OVENS
CO-151-XWUA-5DXM2081BC
HOW TO INSTALL CABINETS:
1 . Remove all packing material from inside and outside of
cabinet .
2 . Position cabinet on level floor; install the cabinet
interior (pan slides) if not already installed .
3 . Plug power cord into proper wall receptacle .
4. MANUAL FILL: Fill water pan with three (3) gallons
of HOT water (see CAUTION) .
5. AUTO FILL: Attach water valve on back bottom of
unit to water supply (see "How to use Automatic fill kit
on page 7) .
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
INSTALLATION INSTRUCTIONS
ELECTRICAL SPECS
(AC SERVICE)
Volts
Ph
Hz.
208
1
60
208
1
60
CAUTION
Use of treated water is recommended for
proper operation and to maintain warranty.
It will reduce scaling.
Humidity Oven
Rev. 1 (8/20)
3 . Most jurisdictions consider our low-temperature ovens
(maximum temperature is 350°F/177°C) as low-heat
appliances not requiring vent hoods .
4 . Installation must conform with local codes . The
authority having jurisdiction of enforcement of
the codes will have the responsibility for making
interpretations of the rules .
POWER SUPPLY REQUIREMENT
ELEC. LOAD
ALL 3 PHASE IS 3 WIRE + GROUND
Amps
Volts
Amps
39
208
50
24
208
30
LOW WATER LIGHT:
MANUAL FILL: When water needs to be added to the
pan, the Low Water Light will stay on and the humidity
function will not work until the pan is refilled.
AUTO FILL: If water level is low and water supply is not
connected, an error code will display after a time limit .
(See MENU SETTINGS to turn auto fill on and off)
Convection
FL-2373-BC
Page 3 of 17
Ph
Volts
NEMA
1
208
1
208
6-50P
6-30P