3) Activation mode of the keys
This parameter programs the functions associated with pressing the key once, if it is pressed
outside the programming menu.
The value to be set is a one-digit number for which a specific function is associated with each
value, according to the following table.
VALUE
0
1
2
3
Reset: reset function of the displayed value, by pressing the button the displayed value is set to
zero.
Preset: preset function of the displayed value; by pressing
becomes equal to the value in the
(when the digit on the right is set to 2).
Fast Preset: the fast setting of the displayed value on the display; by pressing and releasing the
button key the writing
of the preset parameter.
Then you can set a value, with the procedure seen previously. The set value becomes the value
shown on the display at the current position. This function is useful when the altitude on the
display needs to be corrected frequently.

4) Counting direction

It sets the counting direction, allowed values 0 or 1.
By setting 0, the displayed value increases turning the shaft clockwise.
By setting 1, the displayed value decreases turning the hollow shaft clockwise.
5) Counting saving
Allowed values 0-1.
Writing '1' forces the saving of the current position and configuration of the instrument in the non-
volatile memory. This function is only used to not lose the measured position if the battery is removed
for replacement.
Displayed value calibration
After having mounted the instrument on the machine and having set all the parameters, to view the
correct measurement on the display, it is necessary to reset or preset the displayed value.
Place the position of the shaft where the measurement to be displayed is precisely known (e.g.
mechanical stop position) or measure that point on the axis.
Program the parameter
and the
will appear, press again the button for about two seconds and set the measurement
to be displayed on the display. Confirm by holding down the button for about 5 seconds and the
measurement will appear on the display. If the calibration displayed value should be equal to zero,
instead of the preset it is possible to use the reset by setting the value '1' in the parameter
menu, then pressing the button the displayed value on the display will be reset to zero.
Now the instrument is calibrated, the parameter
avoid accidental reset/preset of the value.
Date: 30/10/23
Key disabled: no function will be performed when the key is
mm to inch conversion
parameter, which can be set immediately after
appears; by holding down the button it is possible to modify the value
with the value '3' and exit from programming . Now press the button
File: EP3_ing.doc
Function
pressed
Reset
Preset
the button the displayed value
must be restored to the desired value to
Electronic position indicator