FIAMA EP46RS Kullanım ve Bakım Kılavuzu - Sayfa 8

Ölçüm Cihazları FIAMA EP46RS için çevrimiçi göz atın veya pdf Kullanım ve Bakım Kılavuzu indirin. FIAMA EP46RS 12 sayfaları. Electronic hollow shaft display with serial output

FIAMA EP46RS Kullanım ve Bakım Kılavuzu
Hollow shaft display with serial output
The system (slave) transmits by an instrument MASTER on the serial line through a protocol type MODBUS
RTU words of 8bit; 1 stop bit and parity bit according to the
The physical interface is RS-485. Every EP4-_RS has an identifying address. The protocol is based on a
QUERY/RESPONSE structure: the slave devices reply to the queries with a message that contains the
identifying address and the requested data.
Further Information on the creation of two CRC bytes are available on www.modicon.com.
The activated MODBUS commands are:
0x03: multiple reading of registers
0x10: writing of several registers.
0x06 writing of one registers.
0x03 READING OF REGISTERS
To read the registers of the instrument, the master must send a query composed as follows (every element is
a byte):
ADDRESS | 0x03 | START_REG_HI | START_REG_LO | N_REG_HI | N_REG_LO | CRC_HI | CRC_LO
-
START_REG_HI | START_REG_LO is the address at the starting 16 bit for the reading
-
N_REG_HI | N_REG_LO is the number (16 bit) of the registers to be read
The instrument replies with the following message:
ADDRESS | 0x03 | NBYTE | DATA_1_HI | DATA_1_LO | DATA_2_HI | DATA_2_LO | ... | CRC_HI | CRC_LO
DATA_1_HI | DATA_1_LO | DATA_2_HI | DATA_2_LO | ... is the sequence of the data read.
NBYTE is the number of the given bytes that follow
DATA_1_HI | DATA_1_LO | DATA_2_HI | DATA_2_LO | ... is the stream of data read.
0x10 WRITING OF REGISTERS
To write the registers of the instrument, the master must send a query composed as follows (every element is
a byte):
ADDRESS | 0x10 | START_REG_HI | START_REG_LO | N_REG_HI | N_REG_LO | NBYTE | DATA_1_HI |
DATA_1_LO | DATA_2_HI | DATA_2_LO |...... | CRC_HI | CRC_LO
The instrument replies with the following message:
ADDRESS | 0x10 | START_REG_HI | START_REG_LO | N_REG_HI | N_REG_LO | CRC_HI | CRC_LO
Connection scheme
1 10 ÷ 30VDC positive power supply
2 GND negative power supply
3 RS+ RS485 serial port positive
4 RS– RS485 serial port negative
Male connector: 4 pin M12x1 A-coding.
The pin configuration of both connectors is identical.
Please pay attention: an incorrect electrical connection could damage the unit.
Date: 06/04/21
File: EP4RS_4.1_ing.doc
EP43RS / EP46RS
constant which is set.
1
2
4
3
Rev: 4.1