FIAMA P1X Manuel - Sayfa 3
Valf Konumlandırıcılar FIAMA P1X için çevrimiçi göz atın veya pdf Manuel indirin. FIAMA P1X 11 sayfaları.
function according to the following table:
KEY
1
2
3
4
5
6
7
8
NOTA BENE: in order to ease the association between the wished function and the corresponding number, on
the front panel next to every function indicator it is reported the number corresponding to the associated
function.
1.
MANUAL AXIS MOVEMENT (MAN)
The manual function enables to move the axis forward/backward in slow/fast mode by pressing the
numerical keys according to the following table:
NB: in order to move the axis the EMERGENCY input must be closed.
2.
ZERO SETTING/PRESETTING OR ZERO RESEARCH (ZERO)
Through this function it is possible to zero set or set at a wished value (preset) the dimension of the axis
or to carry out an automatic zero research (with encoder zero notch or zero micro) to zero set or preset
the dimension.
Manual zero setting or presetting
By pressing the E key or by enabling the
carry out a presetting of the dimension as a function of what was set in the constant
Automatic zero setting or presetting (zero research)
By enabling the START input in the terminal box (if the constant
page 7) the zero research is started; it occurs with the backward shifting of the axis at slow speed. When
the axis meets the zero notch the dimension is set to zero and the movement is interrupted.
In order to use this function it is necessary that the zero microswitch (or the proximity switch) is connected
to the
input of the positioner.
PRESET
3.
IMMEDIATE POSITIONING AT A SINGLE DIMENSION (SING)
This mode was created to immediately position the axis at a given dimension without intervening on the
positioning programmes. Press the C key, enter the dimension through the numerical keypad, confirm by
pressing E and close the
about 2 seconds. If the
dimension. Once the axis reached the set position, it is possible to enable the
outputs according to what is set in the
AUX
data: 13/01/16
FUNCTION
ASSOCIATED FUNCTION
INDICATOR
Manual axis movement
MAN
Zero setting/presetting or zero research
ZERO
Immediate positioning at a given dimension
SING
/
Automatic/semiautomatic positioning
A
S
Writing of dimensions and positioning programmes
PROG
Setting of positioner machine parameters
COST
Inputs/outputs tests
TEST
Setting of the number of cycles to be carried out
CYCL
KEY
7 <<
9 >>
4 <
6 >
PRESET
input to start the movement of the axis or hold down the
START
input is closed, the positioner controls the motion to reach the set
EMERGENCY
file: P1X_ing.doc
AXIS MOVEMENT
Backward fast
Forward fast
Backward slow
Forward slow
input in the terminal box it is possible to zero set or to
constant (see page 6)
on page 7
is set to the proper value see
- key for
START
END OF POSITIONING
pag 3 di 11
and