21)Value of the analogue output for the speed Fast
The output value which corresponds to the speed Fast is stated in per cent of the maximum value and
that can be set-up from 1 to 100.
22) Value of the analogue output for the speed Slow
The output value which corresponds to the speed Slow is stated in per cent of the maximum value and
that can be set-up from 1 to 100.
23) Working way for output -10/+10V o 0/10V
Through this constant is possible to select the type of output: setting 0 (driving gear) the output goes from
-10V to +10V, positive voltage for the onward gear and negativ for the backward gear, setting 1 (inverter)
the output goes from 0 to +10V and the gear wise is discriminated by the relay of Forward/Backward.
By using the current output 4/20 mA set this constant to 1.
24) Dimensions lower limit
Due to safety reasons the positioner prevents the entry of dimensions lower than the value set in this
constant and interrupts the axis motion if during the positioning the dimension becomes lower than this
limit. Don't set values that are upper then the Upper Limit for the values (next constant) or the positioner
will not accept the start drives
25) Dimensions upper limit
As for the previous constant, the positioner prevents the entry of dimensions exceeding the value set in
this constant and interrupts the axis motion if during the positioning the dimension exceeds this limit. Don't
set the values that are lower then the Lower Limit for the values (previous constant) or the positioner will
not accept the start drives.
26) Display mode
Setting this function gives the possibility to convert the quota visualized on the display in a quota
expressed in inch fraction or degrees. Keeping pressed the key P for abt. 3 seconds is possible proceed
to a type of visualization to an other.
The constant
select the visualization needed according to the following table
data: 13/01/16
defines the type of conversion of the quota: using keys START- and START+

DISPLAY FUNCTION

From tenth of mm to thousandths of an inch
From tenth of mm to hundredths of an inch
From mm to hundredths of an inch
From mm to tenths of an inch
From cm to hundredths of an inch
Sexagesimal degrees with display in degrees and prime numbers
Sexagesimal degrees with display in degrees
file: P1X_T_ing.doc
disabled
From dm to inches
pag 8 di 11