Digilock Numeris Versa Mini Ürün Kılavuzu - Sayfa 10

RFID Sistemleri Digilock Numeris Versa Mini için çevrimiçi göz atın veya pdf Ürün Kılavuzu indirin. Digilock Numeris Versa Mini 11 sayfaları. Touch rfid
Ayrıca Digilock Numeris Versa Mini için: Manuel (18 sayfalar), Ürün Kılavuzu (11 sayfalar)

Digilock Numeris Versa Mini Ürün Kılavuzu
Support

Sleep Mode

After three consecutive incorrect User Code entries to unlock, the lock will enter Sleep Mode for one minute. For each subsequent incorrect
entry, the lock will remain in Sleep Mode for an additional minute. The keypad is disabled while in Sleep Mode. A valid Manager Key may be
used to unlock while lock is in Sleep Mode.

Low Battery Indicator

After locking or unlocking, the lock emits two sets of three beeps indicating that the batteries are low. Replace the batteries.

Does not Unlock with the User Code or User Key

The lock does not recognize the User Code or User Key. For immediate access, operate with a valid Manager Key. If in assigned use
functionality, follow instructions to Assign User Credentials to assign a new User Code or User Key to the lock.
Does not Operate with a Manager Key
The lock does not recognize the Manager Key. Follow instructions to Add Manager Keys to program the Manager Key to the lock. For
immediate access, operate with another valid Manager Key.
Does not Operate with the Programming Key
The lock does not recognize the Programming Key. If the Programming Key has been replaced, operate with the Replacement
Programming Key. Contact Digilock support for additional assistance.
No Audible Feedback when = is Pressed
The lock may be in Sleep Mode or the batteries may need to be replaced. For immediate access, operate with a valid Manager Key. If the
error condition persists, replace the batteries.

Battery Replacement*

It is not necessary to uninstall the lock from the door.
surface mount
b
a
a.
Remove the screws and the battery pack.
b.
Replace the two premium lithium CR2032 batteries.
c.
Re-Insert battery pack and screws.
*In case of battery failure, operate with a valid Manager Key.
022018
PG-VMSK-AD-DEN
Product Guide
recess mount
c
a.
b.
c.
Keypad
Shared & Assigned Use Functionality
b
a
Remove the screws and the battery cover.
Replace the two premium AAA batteries.
Replace battery cover and screws.
www.digilock.com | [email protected]
c
Phone: 707 766 6000