Digimax 210 Kullanıcı Kılavuzu - Sayfa 7
Termostat Digimax 210 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Digimax 210 11 sayfaları. Programmable thermostat compatible with maxi controller
Ayrıca Digimax 210 için: Kullanıcı Kılavuzu (12 sayfalar)
8) Connection to the the Maxi Controller
a) General operation
You can connect up to 4 DigiMax 210 to the Maxi Controller.
Depending on the information sent by the thermostats, the
Maxi Controller will send X10 messages on the power line
to turn On or Off X10 modules connected to your heaters or
boiler. These X10 modules can be Din appliance modules
(AD10) for boilers working on 230V or Universal modules
(UM7206) for boilers working on low voltage (up to 24V).
Each thermostat transmits the comfort setpoint and the am-
bient temperature. In the Maxi Controller you can enter a tem-
perature setback , between 1 and 9 degrees.
When the Maxi Controller is in "Disarm" or "Arm home" mode,
it will turn On or Off the X10 module connected to the boiler
depending of the ambient temperature and the comfort
setpoint.
When the console is in "Arm Away" mode, the setback differ-
ential to the comfort setpoint is applied. Suppose the ambi-
ent temperature is 15 °C, the comfort setpoint is 20°C, with a
setback of 4°C : the comfort setpoint minus the setback is
20°C - 4°C= 16°C, so the console will send an On message.
Suppose that now the ambient temperature is 19°C, the com-
fort setpoint minus the setback is 20°C - 4°C= 16°C, so the
console will send an OFF message.
Page 7