Cisco 6503 - Catalyst Firewall Security Sys Beyaz Kitap - Sayfa 3
Anahtar Cisco 6503 - Catalyst Firewall Security Sys için çevrimiçi göz atın veya pdf Beyaz Kitap indirin. Cisco 6503 - Catalyst Firewall Security Sys 19 sayfaları. Catalyst 6500 series chassis and module power and heat values
Ayrıca Cisco 6503 - Catalyst Firewall Security Sys için: Ürün Bülteni (6 sayfalar), Tamamlayıcı Kılavuz (3 sayfalar), Veri Sayfası (30 sayfalar), Teknik Bilgiler (16 sayfalar)
The changes to the switching mode are done automatically, depending on the hardware installed. No specific configuration is
necessary on the SFM for typical operation. The current switching mode of the switch fabric module can be monitored through
the Catalyst OS command-line interface (CLI) using the show fabric channel switchmode command. Example 1 shows a
completely fabric-enabled system (all compact mode) and Example 2 shows classic and fabric-enabled line cards in an SFM
system (flow-through and truncated mode).
Example 1: Fabric-Enabled System
The following output is from a configuration with dual supervisor engines, one SFM, and a fabric-enabled line card in slot 3.
Sup2-A> (enable) show fabric channel switchmode
Module Num Fab Chan Fab Chan Switch Mode
------ ------------ -------- ------------ --------------
1
1 0, 0 compact
2
1 0, 1 compact
3
1 0, 2 compact
5
18 0, 0 n/a
5
18 1, 1 n/a
5
18 2, 2 n/a
5
18 3, 3 n/a
5
18 4, 4 n/a
5
18 5, 5 n/a
5
18 6, 6 n/a
5
18 7, 7 n/a
5
18 8, 8 n/a
5
18 9, 9 n/a
5
18 10, 10 n/a
5
18 11, 11 n/a
5
18 12, 12 n/a
5
18 13, 13 n/a
5
18 14, 14 n/a
5
18 15, 15 n/a
5
18 16, 16 n/a
5
18 17, 17 n/a
15
0 n/a
n/a
16
0 n/a
n/a
CLI output description for show fabric channel switchmode:
Num Fab Chan—The number of fabric channels that the module is associated with.
Fab Chan—The first number is the fabric channel number that the module is associated with. The second number is the fabric
channel number that the SFM is associated with.
Switch mode—Possible output is "flow through," "truncated," "compact." Switch mode applies only to line cards with fabric
and bus connections.
Channel status—Possible output is "ok," "sync error," "CRC error," "heartbeat error," "buffer error," "timeout error," or
"unknown." Channel status applies only to line cards with fabric and bus connections.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Channel Status
ok
ok
ok
ok
ok
ok
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
n/a
n/a
Cisco Systems, Inc.
Page 3 of 19