Connecting Power to the Fan Tray
Installing the Fan Tray Power Cable for AC-Input Systems
The fan tray ships with power wires secured at each terminal block. Use these wires to connect the fan
Note
tray to the 3000 W AC-input power supply using the supplied cables. If you have redundant power
supplies, repeat the steps in this section for the redundant power supply.
To connect the high speed fan tray to the 3000 W AC-input power supply, follow these steps:
Connect the female end of the supplied power cable (see
Step 1
the two ends together until you hear a click.
Figure 9
On the power supply, loosen the thumb screw on the external power connector cover and lift up the cover.
Step 2
(See
Figure 10
Connect the male end of the supplied power cable to the female end of the external power connector on
Step 3
the power supply until you hear a click.
If you have redundant power supplies, repeat the steps in this section for the redundant power supply.
Step 4
Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note
14
Cable Connectors
To fan cable
To power supply
Figure
10.)
External Power Connector Cover
OUTPUT 42V /17A
1
42V /17A
OK
Figure
9) to the fan tray wire connector. Press
OUTPUT 42V /17A
2
42V /17A
OK
+
78-16162-02