Cisco AJ732A - MDS 9134 Fabric Switch Yayın Notu - Sayfa 40

Anahtar Cisco AJ732A - MDS 9134 Fabric Switch için çevrimiçi göz atın veya pdf Yayın Notu indirin. Cisco AJ732A - MDS 9134 Fabric Switch 44 sayfaları. Converged network switches for nx-os 4.0(1a)n1(1)
Ayrıca Cisco AJ732A - MDS 9134 Fabric Switch için: Yapılandırma Kılavuzu (49 sayfalar), Yayın Notu (48 sayfalar), Yayın Notu (44 sayfalar), Yayın Notu (36 sayfalar), Yayın Notu (26 sayfalar), Yayın Notu (22 sayfalar), Hızlı Referans Kılavuzu (14 sayfalar), Yayın Notu (3 sayfalar)

Cisco AJ732A -  MDS 9134 Fabric Switch Yayın Notu

Open Caveats

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Open Caveats
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(3)
40
%SME_CPP-SLOT13-3-LOG_ERR_SME_ITL_CPP_ERR: Module:13 Host-Target IT Nexus
I:0xc1f3202015180006 T:0xc5a0202000010006 vsan:3000 oid:0x117 LunID:0x0000
This message is for debugging purposes and is also displayed during the upgrade of an MSM-18/4
module. An upgrade of the MSM-18/4 module where Cisco SME is enabled, is disruptive; however,
this syslog message does not indicate an issue.
Workaround: This issue is resolved.
CSCsm13002
Symptom: In rare cases, if a READ command issued by Cisco SME for media identification is
dropped or lost, the tape is marked as a clear-text tape. Subsequently, a CHECK_CONDITION with
ILI is returned when a READ is issued by the host. This can cause a backup application to mark the
tape as read-only.
Workaround: This issue is resolved.
CSCsm17768
Symptom: There is a observable performance drop for backup and restore when Cisco SME is
introduced between a host and tape due to the increased latency.
Workaround: This issue is resolved.
CSCsl71227
Symptom: Using Fabric Manager Release 3.2(2), if you have an enclosure with multiple ports and
you then use the Data Migration Wizard to create a job with that enclosure as the existing storage
but don't select all the storage ports in the enclosure, an error is displayed in the creation wizard.
Workaround: Put the ports you plan to use as the existing storage in the migration into a separate
enclosure, and use that enclosure in the wizard selection.
CSCsk35725
Symptom: Fabric Manager takes 2 to 3 minutes to bring up the DMM job creation wizard in a setup
with 25 switches, 400 enclosures, and 2400 entries in the name server.
Workaround: None.
CSCso49196
Symptom: During an upgrade from SAN-OS Release 3.2(3a) to Release 3.3(1a), when a switchover
occurs to the Supervisor running Release 3.3(1a), Cisco SME traffic flows for hosts that are not
connected locally to the switch that is getting upgraded, may get flapped for a very short time. This
can also occur during a switchover to a Supervisor running Release 3.3(1a).
Workaround: None.
CSCsq20408
Symptom: After creating SANTap Control Virtual Targets (CVTs) or SANTap Data Virtual Targets
(DVTs), the running-configuration and the startup-configuration are not synchronized. Output from
the show startup-config command will be different from the output of the show running-config
and the startup configuration will not display SANTap configuration information.
Workaround: Issue the copy running-startup command whenever you create SANTap Control
Virtual Targets (CVTs) or SANTap Data Virtual Targets (DVTs) so that the running configuration
and the startup configuration are synchronized.
.
OL-14116-11