Accustic Arts MONO III MK2 Manuel - Sayfa 11

Amplifikatör Accustic Arts MONO III MK2 için çevrimiçi göz atın veya pdf Manuel indirin. Accustic Arts MONO III MK2 13 sayfaları.

VERY
WARNING!
IMPORTANT!
After switching the unit off please wait 60 seconds before switching it on again.
6 Looking after your amplifier
This unit from ACCUSTIC ARTS
quality devices. Clean the housing with a dry or slightly moistened cloth. Please do not use any aggressive
detergents or detergents which contain silicon.
The best way to clean the chromed front plate is with a mild non-aggressive fat-dissolving detergent (e.g. glass
cleaner). Use a very soft clean cloth and wipe the front plate with this without exerting strong pressure. Never use
abrasive agents or polishing agents with abrasive particles.
CAUTION ! DANGER OF FIRE !
VERY
IMPORTANT!
Never place the unit in direct sunshine and avoid extreme changes in temperature.

7 Troubleshooting

Malfunctions are mostly caused by something simple which can be put right quickly.
In the next section some possible malfunctions are described together with their corrective action. However, if it is
not possible to remove the malfunction please contact your authorized dealer.
Malfunction
The unit is switched on, the blue LED is illuminated but you hear no music.
Cause 1
The interconnect or speaker cables are not properly connected.
Solution
Switch off all units and check all connections
Cause 2
MUTE switch is activated.
Solution
Turn on the MUTE switch (see chapter
Malfunction
The left or right LEDs do not go out approx. 5 seconds after switching on the unit or light up
during operation.
Cause 1
Clipping due to overload of the power amplifier.
Solution
Lower the volume on your control device (e.g. preamplifier).
Cause 2
Overheating of the unit.
Solution
Switch off the unit for approx. 30 minutes and then make sure that the unit has adequate
cooling.
Cause 3
Short circuit at speaker outlet.
Solution
Check the loudspeaker terminals and correct it if necessary
Malfunction
Crackling or humming in the loudspeaker.
Cause
Contact problems on the input sockets or on the loudspeaker terminals.
Solution
Switch off the unit and check the contact on the input sockets and on the loudspeaker terminals.
®
does not require special treatment in excess of the usual care taken with high
4.
3).
12