This parameter provides backward compatibility with controllers not
supporting Z-Wave+.
Available settings: 0 - backward compatible tamper alarm sent to
Default setting:
40. Illuminance report - threshold
This parameter determines the change in light intensity level result-
ing in illuminance report being sent to the main controller.
Available settings: 0 - reports are not sent
Default setting:
42. Illuminance report - interval
Time interval between consecutive illuminance reports. The reports
are sent even if there is no change in the light intensity.
Available settings: 0 - periodical reports are not sent
Default setting:
60. Temperature report - threshold
This parameter determines the change in measured temperature that
will result in new temperature report being sent to the main controller.
Available settings: 0 - reports are not sent
Default setting:
62. Temperature measuring - interval
Time interval between consecutive temperature measurements. The
shorter the time, the more frequently the temperature will be meas-
ured, but the battery life will shorten.
Available settings: 0 - temperature is not measured
Default setting:
64. Temperature report - interval
Time interval between consecutive temperature reports. The reports
are sent even if there is no change in the temperature.
Available settings: 0 - periodical reports are not sent
Default setting:
5th association group
1 - backward compatible tamper alarm sent in
broadcast mode
0
Parameter size:
1-32767 (illuminance in lux)
200 (200 lux) Parameter size:
1-32767 (in seconds)
3600 (1h)
Parameter size:
1-255 (0.1-25.5°C, 0.1°C step)
10 (1°C)
Parameter size:
1-32767 (in seconds)
900 (900s)
Parameter size:
1-32767 (in seconds)
0
Parameter size:
1 [byte]
2 [bytes]
2 [bytes]
2 [bytes]
2 [bytes]
2 [bytes]
ADvAnCED PARAMETERS
15
i
NOTE
Frequent illuminance
reports will shorten
the battery life. Pa-
rameter value under
5 may result in block-
ing the temperature
reports.
i
NOTE
Temperature
meas-
urements
are
still
performed during the
wake up, even if the
periodic measuring is
disabled
(parameter
62 set to 0).
i
NOTE
Frequent temperature
reports will shorten
the battery life. Pa-
rameter value under
5 may result in block-
ing the illuminance
reports.