Sharp Carousel R-350F Servis Kılavuzu - Sayfa 13

Mikrodalga Fırın Sharp Carousel R-350F için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Sharp Carousel R-350F 36 sayfaları. R-350f microwave oven

PROCEDURE
LETTER
If incorrect readings are obtained, replace the motor.
CARRY OUT 4R CHECKS
H
BLOWN FUSE F10A
CARRY OUT 3D CHECKS.
1. If the fuse F10A is blown, there could be shorts or ground in electrical parts or wire harness.
Check them and replace the defective parts or repair the wire harness.
2. If the fuse F10A is blown when the door is opened, check the 1st. latch switch, 2nd. interlock relay
and monitor switch.
If the fuse F10A is blown by incorrect door switching replace the defective switch(s) and the fuse
F10A.
CARRY OUT 4R CHECKS.
CAUTION: ONLY REPLACE FUSE F10A WITH THE CORRECT VALUE REPLACEMENT
I
NOISE FILTER TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of the noise
filter. Using an ohmmeter, check between the termi-
nals as described in the following table.
MEASURING POINT
Between N and L
Between terminal N and WHITE
Between terminal L and RED
If incorrect readings are obtained, replace the noise filter unit.
CARRY OUT 4R CHECKS.
J
HIGH VOLTAGE FUSE TEST
CARRY OUT 3D CHECKS.
If the high voltage fuse is blown, there could be a short in the high voltage rectifier or the magnetron.
Check them and replace the defective parts and high voltage fuse.
CARRY OUT 4R CHECKS.
CAUTION: ONLY REPLACE THE HIGH VOLTAGE FUSE WITH THE CORRECT VALUE RE-
K
TOUCH CONTROL PANEL ASSEMBLY TEST
The touch control panel consists of circuits including semiconductors such as LSI, ICs, etc. Therefore,
unlike conventional microwave ovens, proper maintenance cannot be performed with only a
voltmeter and ohmmeter. In this service manual, the touch control panel assembly is divided into two
units, Control Unit and Key Unit, and also the Control Unit is divided into two units, CPU Unit and
Power Unit, and troubleshooting by unit replacement is described according to the symptoms
indicated.
TEST PROCEDURES
Table: Resistance of Motor
Motors
Fan motor
Turntable motor
INDICATION OF
OHMMETER
Open circuit
Short circuit
Short circuit
PLACEMENT
COMPONENT TEST
Resistance
Approximately 405
Approximately 14.8 k
N
L
L (min)
600 H
11
R-350F
Cx
L
WHT
L
RED
Cy
Cx
20%
Cy
20%
0.068 F
0.0022 F