PROCEDURE
LETTER
STEPS
1
2
3
4
NOTE: At the time of these repairs, make a visual
CARRY OUT 4R CHECKS.
TEST PROCEDURES (CONT'D)
OCCURANCE
The rated voltage is not applied to POWER
terminal of CPU connector (CN-A)
The rated voltage is applied to primary side of
power transformer.
Only pattern at "a" is broken.
Pattern at "a" and "b" are broken.
inspection of the varistor for burning damage
and examine the transformer with tester for
the presence of layer short-circuit (check
primary coil resistance). If any abnormal
condition is detected, replace the defective
parts.
COMPONENT TEST
CAUSE OR CORRECTION
Check supply voltage and oven main unit.
Power transformer or secondary circuit defective. Check
and repair.
*Insert jumper wire J1 and solder.
*Insert the coil RCILF2003YAZZ between "c" and "d".
13