The following is a description of component functions
during oven operation.
Relay and Components Connection
RELAY
CONNECTED COMPONENT
RY1
Oven lamp/ Turntable motor
RY2
Power transformer
RY3
Convection heater
RY4
Damper motor
RY5
Convection motor
RY6
Fan motor
OFF CONDITION
Closing the door activates all door interlock switches:
upper latch switch, lower latch switch and stop switch. (In
this condition, the monitor switch contacts are closed.)
When oven is plugged in a wall outlet (230 - 240V, 50Hz),
rated voltage is supplied to the control unit. (Figure O-1):
1. The display flashes "SHARP", "MICRO-", "WAVE",
'OVEN".
To set any programmes or set the clock, you must first
touch the STOP/CLEAR pad.
" : " appears in the display and the time counts up
every minute.
NOTE: When the oven door is opened, the oven lamp
comes on at this time.
2. A signal is input to the control unit, energizing the coil
of shut-off relay (RY4).
RY4 contacts close, completing a circuit to the damper
motor. The damper motor now operates moving the
damper to the open position, thereby closing the
contacts of damper switch inputs a signal to the control
unit.
The coil of relay RY4 is de-energized, opening its
contacts, thereby turning off the damper motor.
MICROWAVE COOKING CONDITION
HIGH COOKING
Enter cooking time by pressing the NUMBER pads and
then select microwave cooking and power level by press-
ing the POWER LEVEL pad. When the START pad is
touched, the following operations occur:
1. The contacts of relays are closed and components
connected to relays are turned on (RY1, RY2, RY6).
(Figure O-2)
2. Rated voltage is supplied to the primary winding of the
power transformer. The voltage is converted to about
3.3 volts A.C. output on the filament winding and high
voltage of approximately 2260 volts A.C. on the high
voltage winding.
3. The filament winding voltage (3.3 volts) heats the
magnetron filament and the high voltage (2260 volts) is
sent to the voltage doubling circuit.
4 The 2450 MHz microwave energy produced in the
magnetron generates a wave length of 12.24 cm. This
energy is channelled through the waveguide (transport
channel) into the oven cavity, where the food is placed
to be cooked.
OPERATION SEQUENCE
5. Upon completion of the cooking time, the power
transformer, oven lamp, etc. are turned off and the
generation of microwave energy is stopped. The oven
will revert to the OFF condition..
6 When the door is opened during a cook cycle, the
monitor switch, upper latch switch, lower latch switch
and stop switch are activated with the following results.
The circuits to the turntable motor, cooling fan motor
and high voltage components are de-energized, the
oven lamp remains on and the digital read-out displays
the time still remaining in the cook cycle when the door
was opened.
7. The monitor switch is electrically monitoring the
operation of the upper latch switch and lower latch
switch and is mechanically associated with the door so
that it will function in the following sequence.
1) When the door opens from a closed potion, the upper
latch switch and the lower latch switch open their
contacts, and then the monitor switch contacts close.
2) When the door is closed, from the open position, the
monitor switch contacts first open, and then the contacts
of the upper latch switch and lower latch switch must be
closed.
If the common and normal open contacts of upper latch
switch and the lower latch switch fail with their contacts
closed when the door is opened, the closing of the monitor
switch contacts will form a short circuit through the fuse,
upper latch switch and the lower latch switch, causing the
monitor fuse to blow.
MEDIUM HIGH, MEDIUM, MEDIUM LOW, LOW
COOKING
When variable cooking power is programmed, the rated
voltage is supplied to the power transformer intermittently
through the contacts of the relay (RY2) which is operated
by the control unit within a 32-second time base. Micro-
wave power operation is follows:
VARI MODE
HIGH (100% power)
MED HIGH (approx. 70% power)
MED (approx. 50% power)
MED LOW (approx. 30% power)
LOW (approx. 10% power)
NOTE: The ON/OFF time ratio does not exactly correspond
CONVECTION COOKING CONDITION
PREHEATING CONDITION
Press the PREHEAT pad and then select preheating
temperature by pressing the temperature pad. When the
START pad is touched, the following operations occur:
1. The coil of shut-off relays RY1+RY5+RY6 are
energized, the oven lamp, cooling fan motor, turntable
motor and convection motor are turned on.
2. The coil of relay (RY4) is energized by the CPU unit.
The damper is moved to the closed position, opening
the damper switch contacts. The opening of the damper
switch contacts sends a signal to the LSI on the CPU
4
to the percentage of microwave power, because
approx. 2 seconds are needed for heating up the
magnetron filament.
ON TIME
OFF TIME
32 sec.
0 sec.
24 sec.
8 sec.
18 sec.
14sec.
12 sec.
20 sec.
6 sec.
26 sec.